Determination of trace elements in serum by dynamic reaction cell inductively coupled plasma mass spectrometry - Developing of a method with a desolvating system nebulizer

被引:46
作者
D'Ilio, S. [1 ]
Violante, N. [1 ]
Caimi, S. [1 ]
Di Gregorio, M. [1 ]
Petrucci, F. [1 ]
Senofonte, O. [1 ]
机构
[1] Ist Super Sanita, Dept Environm & Primary Prevent, I-00161 Rome, Italy
关键词
trace elements; dynamic reaction cell inductively coupled plasma mass spectrometry; serum; desolvating system;
D O I
10.1016/j.aca.2006.05.010
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
An inductively coupled plasma mass spectrometer (ICP-MS), equipped with a dynamic reaction cell (DRC) and coupled with a desolvating nebulizing system (Apex-ACM) to reduce the oxide formation, was used in the determination of Al, Co, Cr, Mn, Ni and Se in serum samples. The effect of the operating conditions of the DRC system was studied to get the best signal-to-background (S/B) ratio. The potentially interfering molecular ions at the masses m/z(27)Al, Co-59, Cr-52, Mn-55, Ni-60 and Se-78, were significantly reduced in intensity by using NH3 and H-2, as the reaction cell gases in the DRC, while a proper Dynamic Bandpass Tuning parameter q (RPq) value was optimized. The detection limits for Al-27, Co-59, Cr-52, Mn-55 Ni-60 and Se-71, estimated with 3-sigma method, resulted to be 0.14, 0.003, 0.002, 0.01, 0.01 and 1.8 mu g L-1, respectively. This analytical method was developed on both a human serum certified reference material and a lyophilized animal serum produced and proposed in an intercomparison study. The results obtained for the reference samples agreed satisfactorily with the certified values. Precision (expressed as CV%) between sample replicates was better than 10% for elements determination, with the only exception of aluminium (14%). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:432 / 438
页数:7
相关论文
共 32 条
[1]
Reaction chemistry and collisional processes in multipole devices for resolving isobaric interferences in ICP-MS [J].
Bandura, DR ;
Baranov, VI ;
Tanner, SD .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (05) :454-470
[2]
A dynamic reaction cell for inductively coupled plasma mass spectrometry (ICP-DRC-MS) - Part 1. The rf-field energy contribution in thermodynamics of ion-molecule reactions [J].
Baranov, VI ;
Tanner, SD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (08) :1133-1142
[3]
Relationships between trace element concentrations in human blood and serum [J].
Bárány, E ;
Bergdahl, IA ;
Bratteby, LE ;
Lundh, T ;
Samuelson, G ;
Schütz, A ;
Skerfving, S ;
Oskarsson, A .
TOXICOLOGY LETTERS, 2002, 134 (1-3) :177-184
[4]
Trace elements in blood and serum of Swedish adolescents:: Relation to gender, age, residential area, and socioeconomic status [J].
Bárány, E ;
Bergdahl, IA ;
Bratteby, LE ;
Lundh, T ;
Samuelson, G ;
Schütz, A ;
Skerfving, S ;
Oskarsson, A .
ENVIRONMENTAL RESEARCH, 2002, 89 (01) :72-84
[5]
Aluminum as a toxicant [J].
Becaria, A ;
Campbell, A ;
Bondy, SC .
TOXICOLOGY AND INDUSTRIAL HEALTH, 2002, 18 (07) :309-320
[6]
Determination of calcium, iron and zinc in milk powder by reaction cell inductively coupled plasma mass spectrometry [J].
Chen, KL ;
Jiang, SJ .
ANALYTICA CHIMICA ACTA, 2002, 470 (02) :223-228
[7]
Rapid multi-element analysis of groundwater by high-resolution inductively coupled plasma mass spectrometry [J].
Cheng, Z ;
Zheng, Y ;
Mortlock, R ;
van Geen, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (03) :512-518
[8]
Manganese toxicity upon overexposure [J].
Crossgrove, J ;
Zheng, W .
NMR IN BIOMEDICINE, 2004, 17 (08) :544-553
[9]
Sequential thoracentesis -: Minor change of zinc compared to other selected essential trace elements in the serum [J].
Domej, W ;
Tilz, GP ;
Demel, U ;
Földes-Papp, Z ;
Rabold, T ;
Goessler, W ;
Krachler, M ;
Lang, J .
BIOLOGICAL TRACE ELEMENT RESEARCH, 2002, 87 (1-3) :29-43
[10]
COLLISIONAL FOCUSING EFFECTS IN RADIO-FREQUENCY QUADRUPOLES [J].
DOUGLAS, DJ ;
FRENCH, JB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) :398-408