Validation of the Omron HEM-907 device for blood pressure measurement

被引:234
作者
El Assaad, MA [1 ]
Topouchian, JA [1 ]
Darné, BM [1 ]
Asmar, RG [1 ]
机构
[1] Inst CardioVasc, F-75016 Paris, France
关键词
Omron HEM-907; blood pressure measuring device; validation; international protocol;
D O I
10.1097/00126097-200208000-00006
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background The aim of this study was to validate the Omron HEM-907 blood pressure (BP) measuring device according to the international validation protocol. Design The international validation protocol is divided into two phases: the first phase is performed on 15 selected subjects and if the device passes this phase, 18 more subjects are selected making a total number of 33 subjects on which the final validation is performed. Methods For each subject, BP measurements were performed simultaneously by two trained observers using mercury sphygmomanometers alternately with the Omron HEM-907 device. In all, 99 measurements were obtained for comparison. The difference between the BP value given by the device and that obtained by the two observers (mean of the two observers) was calculated for each measure. Results The difference between the two observers was -1 +/- 2 mmHg for the systolic BP (SBP) and for the diastolic BP (DBP). The Omron HEM-907 passed the first phase of the validation process. For the second phase, the average differences between the device and mercury sphygmomanometer readings were -1 +/- 7 and -5 +/- 6 mmHg for SBP and DBP respectively. Readings for the HEM-907 device differed by less than 5 mmHg for 61 of the systolic readings and 52 of the diastolic readings; by less than 10 mmHg for 85 of the systolic readings and 85 of the diastolic readings; and by less than 15 mmHg for 94 of the systolic readings and 96 of the diastolic readings. Conclusions The Omron,HEM-907 device passes the two phases of the international validation protocol. (C) 2002 Lippincott Williams Wilkins.
引用
收藏
页码:237 / 241
页数:5
相关论文
共 12 条
  • [1] [Anonymous], 1987, NAT STAND EL AUT SPH
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] CHARACTERIZATION OF THE OSCILLOMETRIC METHOD FOR MEASURING INDIRECT BLOOD-PRESSURE
    GEDDES, LA
    VOELZ, M
    COMBS, C
    REINER, D
    BABBS, CF
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1982, 10 (06) : 271 - 280
  • [4] *GROUP EV MES SOC, 1998, PRIS TENS ART CAB ME
  • [5] Proposals for simplifying the validation protocols of the British Hypertension Society and the Association for the Advancement of Medical Instrumentation
    O'Brien, E
    [J]. BLOOD PRESSURE MONITORING, 2000, 5 (01) : 43 - 45
  • [6] O'Brien E, 2000, BLOOD PRESS MONIT, V5, P93
  • [7] O'Brien E., 1993, J HYPERTENSION S2, V11, P43, DOI DOI 10.1097/00004872-199306000-00013
  • [8] OBRIEN E, 1994, J HYPERTENS, V12, P1089
  • [9] THE BRITISH-HYPERTENSION-SOCIETY PROTOCOL FOR THE EVALUATION OF AUTOMATED AND SEMIAUTOMATED BLOOD-PRESSURE MEASURING DEVICES WITH SPECIAL REFERENCE TO AMBULATORY SYSTEMS
    OBRIEN, E
    PETRIE, J
    LITTLER, W
    DESWIET, M
    PADFIELD, PL
    OMALLEY, K
    JAMIESON, M
    ALTMAN, D
    BLAND, M
    ATKINS, N
    [J]. JOURNAL OF HYPERTENSION, 1990, 8 (07) : 607 - 619
  • [10] OBRIEN E, 1990, J HYPERTENS S6, V8, P11