Aerosol delivery during mechanical ventilation to the rat

被引:14
作者
Hofstetter, C
Flonder, M
Thein, E
Hoeg, S
Kemming, GI
Kisch-Wedel, H
Kreyling, WG
Zwissler, B
机构
[1] Univ Frankfurt, Dept Anaesthesiol, D-60590 Frankfurt, Germany
[2] Univ Munich, Inst Surg Res, D-8000 Munich, Germany
[3] Univ Munich, Dept Anaesthesiol, D-8000 Munich, Germany
[4] GSF Natl Res Ctr Environm & Hlth, Inst Inhalat Biol, Neuherberg, Germany
关键词
aerosol; animal experimentation; nebulizers;
D O I
10.1080/01902140490489126
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The authors have adjusted a jet nebulizer to a mechanical ventilator (Servo Ventilator, Siemens) to deliver an aerosol to rats. They aimed to clarify whether a modified jet nebulizer generating particles with a mass median aerodynamic diameter of 2 mm would be effective and safe in intubated ventilated rats. Fluorescent microspheres (diameter: 1.0 mm) were aerosolized to verify qualitatively and quantitatively intrapulmonary deposition. Particle deposition fraction was 3.8% (1.3%) of the delivered dose (median [interquartile range]). There was no evidence for any adverse event as assessed from heart rate, mean arterial pressure, PaO2 and PaCO2 before, during, and after nebulization. No pulmonary tissue trauma was detected histologically.
引用
收藏
页码:635 / 651
页数:17
相关论文
共 45 条
[1]  
[Anonymous], 1988, ANN OCCUP HYG, DOI [DOI 10.1093/ANNHYG/32.INHALED_, DOI 10.1093/ANNHYG/32.INHALED_PARTICLES_VI.53]
[2]   SELECTIVE DEPOSITION OF INHALED AEROSOLS TO MECHANICALLY VENTILATED RABBITS [J].
DAHLBACK, M ;
WOLLMER, P ;
JONSON, B .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1994, 7 (04) :315-324
[3]  
DAHLBACK M, 1989, J AEROSOL MED, V2, P339
[4]   Inhaled bronchodilator therapy in mechanically ventilated patients [J].
Dhand, R ;
Tobin, MJ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 156 (01) :3-10
[5]   AEROSOL THERAPY IN MECHANICALLY VENTILATED PATIENTS [J].
DURBIN, CD .
CHEST, 1994, 106 (02) :336-337
[6]  
Ferron G. A., 1976, Journal of Aerosol Science, V7, P5, DOI 10.1016/0021-8502(76)90003-3
[7]  
FERRON GA, 1979, AEROSOLS SCI MED TEC, P163
[8]  
FINCH S, 1999, INTERSURGICAL TECHNI, V1, P1
[9]   Effects of local and systemic budesonide on allergen-induced airway reactions in the pig [J].
Fornhem, C ;
Dahlback, M ;
Kumlin, M ;
Lundberg, JM ;
Alving, K .
BRITISH JOURNAL OF PHARMACOLOGY, 1996, 118 (04) :989-997
[10]   PRESSURIZED AEROSOL VERSUS JET AEROSOL DELIVERY TO MECHANICALLY VENTILATED PATIENTS - COMPARISON OF DOSE TO THE LUNGS [J].
FULLER, HD ;
DOLOVICH, MB ;
POSMITUCK, G ;
PACK, WW ;
NEWHOUSE, MT .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1990, 141 (02) :440-444