Investigations into the use of an ultrasonic chisel to cut bone. Part 1: forces applied by clinicians

被引:43
作者
Khambay, BS [1 ]
Walmsley, AD [1 ]
机构
[1] Univ Birmingham, Sch Dent, Birmingham B6 4NN, W Midlands, England
关键词
ultrasonic chisel; bone cutting; oral surgery;
D O I
10.1016/S0300-5712(99)00043-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To measure in vitro the direction and force of applied loads applied by clinicians when using both a conventional slow surgical handpiece (CH) and an ultrasonic chisel (USC) for cutting bone. Study design: Five clinicians were asked to cut bovine bone using either an USC or a CH. The bone was placed on a force measurement system that could measure both longitudinal and downward loads. The rate of cut was calculated over a fixed time-period and the depth of cut measured using a penetratometer. Results: The magnitude of the longitudinal forces generated varied between 1.48 and 3.22 N (USC) and 0.04 and 4.56 N (CH). The CH had a pulling force directed towards the operator. Both instruments produced a similar range of downward forces although there was intra- and inter-operator variability. The rate of cut varied in a similar manner, however, the CH produced a significantly greater depth of cut (p < 0.05). Conclusions: The force measurement system demonstrated differences in the way clinicians used the USC and CH instruments to cut bone. Of the two cutting methods investigated, the rotary bur is more efficient than the ultrasonic chisel. An ultrasonic chisel does cut bone in a different manner from a conventional bur and clinicians may require training before using it clinically. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:31 / 37
页数:7
相关论文
共 13 条
[1]  
Balamuth L, 1963, Sound: Its Uses and Control, V2, P15
[2]  
Catuna MC., 1953, ANN DENT, V112, P256
[3]   DEPTH OF CURE OF RADIATION-ACTIVATED MATERIALS - EFFECT OF MOLD MATERIAL AND CAVITY SIZE [J].
HARRINGTON, E ;
WILSON, HJ .
JOURNAL OF DENTISTRY, 1993, 21 (05) :305-311
[4]   CLINICAL-APPLICATIONS OF ULTRASONIC INSTRUMENTATION IN THE SURGICAL REMOVAL OF BONE [J].
HORTON, JE ;
TARPLEY, TM ;
JACOWAY, JR .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1981, 51 (03) :236-242
[5]   HEALING OF SURGICAL DEFECTS IN ALVEOLAR BONE PRODUCED WITH ULTRASONIC INSTRUMENTATION, CHISEL, AND ROTARY BUR [J].
HORTON, JE ;
TARPLEY, TM ;
WOOD, LD .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1975, 39 (04) :536-546
[6]  
Johnson WN, 1957, J Periodontol, V28, P264
[7]  
NIELSEN AG, 1954, J DENT RES, V33, P698
[8]  
OMAN C R, 1955, J Am Dent Assoc, V50, P414
[9]  
Postle HH, 1958, J PROSTHET DENT, V8, P153, DOI [10.1016/0022-3913(58)90027-1, DOI 10.1016/0022-3913(58)90027-1]
[10]  
ROCHE HAP, 1954, BR DENT J, V97, P96