Passive sampling

被引:302
作者
Górecki, T
Namiesnik, J
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
[2] Gdansk Univ Technol, Fac Chem, PL-80952 Gdansk, Poland
基金
加拿大自然科学与工程研究理事会;
关键词
air analysis; biomonitoring; passive techniques; sample preparation; sampling; water analysis;
D O I
10.1016/S0165-9936(02)00407-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Passive sampling is based on free flow of analyte molecules from the sampled medium to a collecting medium as a result of a difference in chemical potentials. It can be used for the determination of both inorganic and organic compounds in a variety of matrices, including air, water and soil. The devices used for passive sampling are usually based on diffusion through a well-defined diffusion barrier or permeation through a membrane. Living organisms can also be used as passive samplers. in most cases, passive sampling vastly simplifies sampling and sample preparation, eliminates power requirements, and significantly reduces the costs of analysis. The technique is particularly suited to the determination of time-weighted average concentrations. (C) 2002 Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:276 / 291
页数:16
相关论文
共 129 条
[1]   Offshore passive soil vapor survey at a contaminated coastal site [J].
Anderson, M ;
Church, G .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1998, 124 (06) :555-563
[2]  
BAILEY A, 1977, Annals of Occupational Hygiene, V20, P345, DOI 10.1093/annhyg/20.4.345
[3]  
BAILEY A, 1981, TRACE ORGANIC SAMPLE, P45
[4]   NEW PERSONAL SAMPLER FOR ORGANIC VAPORS [J].
BAMBERGER, RL ;
ESPOSITO, GG ;
JACOBS, BW ;
PODOLAK, GE ;
MAZUR, JF .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1978, 39 (09) :701-708
[5]   PASSIVE SAMPLING FOR VOLATILE ORGANIC-COMPOUNDS (VOCS) IN AIR AT ENVIRONMENTALLY RELEVANT CONCENTRATION LEVELS [J].
BEGEROW, J ;
JERMANN, E ;
KELES, T ;
RANFT, U ;
DUNEMANN, L .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (06) :549-554
[6]   EVALUATION TESTS AND APPLICATIONS OF A DOUBLE-LAYER TUBE-TYPE PASSIVE SAMPLER [J].
BERTONI, G ;
CANEPARI, S ;
ROTATORI, M ;
FRATARCANGELI, R ;
LIBERTI, A .
JOURNAL OF CHROMATOGRAPHY, 1990, 522 :285-294
[7]  
Bjorkholm E., 1990, APPL OCCUP ENV HYG, V5, P767
[8]   A passive sampler for monitoring urban particulate: Preliminary results [J].
Brown, RC ;
Thorpe, A ;
Hemingway, MA .
ENVIRONMENTAL MONITORING AND ASSESSMENT, 1998, 52 (1-2) :19-28
[9]   THE USE OF DIFFUSIVE SAMPLERS FOR MONITORING OF AMBIENT AIR [J].
BROWN, RH .
PURE AND APPLIED CHEMISTRY, 1993, 65 (08) :1859-1874
[10]  
BROWN RH, 1984, IDENTIF ANAL ORG POL, P37