Uncontrolled generator operation of interior PM synchronous machines following high-speed inverter shutdown

被引:92
作者
Jahns, TM [1 ]
Caliskan, V [1 ]
机构
[1] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
关键词
generator; interior permanent magnet synchronous machine; inverter shutdown;
D O I
10.1109/28.806049
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Interior permanent magnet (IPM) synchronous machine drives are vulnerable to a special fault mode when gating is suddenly removed from the inverter switches during highspeed operation. The resulting IPM machine operation as a generator in combination with an uncontrolled rectifier must be properly understood and accounted for in the machine design to avoid damage to either the machine or inverter. An approximate closed-form solution is derived in this paper which relates the resulting machine phase current (and torque) to the IPM machine parameters, the de-link voltage, and the rotor speed. The resulting operating characteristics are particularly interesting for IPM machines that have been designed with inductance saliency ratios greater than 2 (i.e., high-saliency machines). The validity of the approximate solution is confirmed using dynamic simulation results, and the implications of these results for the machine designer seeking to minimize or eliminate the impact of this undesired operating mode are thoroughly discussed.
引用
收藏
页码:1347 / 1357
页数:11
相关论文
共 14 条
[1]  
ADNANES AK, 1992, IEEE POWER ELECTRON, P958, DOI 10.1109/PESC.1992.254780
[2]  
ADNANES AK, 1991, PESC 91 RECORD, P695, DOI 10.1109/PESC.1991.162751
[3]  
ADNANES AK, 1991, IEEE IAS, P169
[4]  
Boldea I., 1996, Reluctance synchronous machines and drives
[5]  
Fratta A., 1990, P INT C EL MACH, P1059
[7]  
KING RD, 1990, P 10 INT EL VEH S, P878
[8]  
KRAUSE PC, 1995, ANAL ELECT MACHINERY, P499
[9]   EXPANSION OF OPERATING LIMITS FOR PERMANENT-MAGNET MOTOR BY CURRENT VECTOR CONTROL CONSIDERING INVERTER CAPACITY [J].
MORIMOTO, S ;
TAKEDA, Y ;
HIRASA, T ;
TANIGUCHI, K .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1990, 26 (05) :866-871
[10]   POWER CAPABILITY OF SALIENT POLE PERMANENT-MAGNET SYNCHRONOUS MOTORS IN VARIABLE SPEED DRIVE APPLICATIONS [J].
SCHIFERL, RF ;
LIPO, TA .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1990, 26 (01) :115-123