Coagulation, fibrinolysis, and cell activation in patients and shed mediastinal blood during coronary artery bypass grafting with a new heparin-coated surface

被引:49
作者
Johnell, M
Elgue, G
Larsson, R
Larsson, A
Thelin, S
Siegbahn, A [1 ]
机构
[1] Univ Hosp, Dept Med Sci, Lab Coagulat Res, SE-75185 Uppsala, Sweden
[2] Univ Hosp, Dept Oncol, Uppsala, Sweden
[3] Univ Hosp, Dept Radiol, Uppsala, Sweden
[4] Univ Hosp, Dept Clin Immunol, Uppsala, Sweden
[5] Univ Hosp, Dept Cardiothorac Surg, Uppsala, Sweden
基金
英国医学研究理事会;
关键词
D O I
10.1067/mtc.2002.122551
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Heparin coating of the cardiopulmonary bypass circuit is shown to improve the biocompatibility of the surface. We have studied a new heparin surface, the Corline Heparin Surface, applied to a complete set of an extracorporeal device used during coronary artery bypass grafting in terms of activation of inflammation, coagulation. and fibrinolysis in patients and in shed mediastinal blood. Methods: Sixty patients scheduled for coronary artery bypass grafting were randomized to one of 3 groups with heparin-coated devices receiving either a standard. high, or low dose of systemic heparin or to an uncoated but otherwise identical circuit receiving a standard dose of systemic heparin. Samples were drawn before, during, and after the operation from the pericardial cavity and in shed mediastinal blood. No autotransfusion of shed mediastinal blood was performed. Results: The Corline Heparin Surface significantly reduced the activation of coagulation, fibrinolysis, platelets, and inflammation compared with that seen with the uncoated surface in combination with a standard dose of systemic heparin during cardiac surgery with cardiopulmonary bypass. Both a decrease and an increase of systemic heparin in combination with the coated heparin surface resulted in higher activation of these processes. A significantly higher expression of all studied parameters was found in the shed mediastinal blood compared with in systemic blood at the same time. Conclusions: The Corline Heparin Surface used in cardiopulmonary bypass proved to be more biocompatible than an uncoated surface when using a standard systemic heparin dose. The low dose of systemic heparin might not be sufficient to maintain the antithrombotic activity, and the high dose resulted in direct cell activation rather than a further anti-inflammatory and anticoagulatory effect.
引用
收藏
页码:321 / 332
页数:12
相关论文
共 44 条
[1]   Effect of anticoagulation protocol on outcome in patients undergoing CABG with heparin-bonded cardiopulmonary bypass circuits [J].
Aldea, GS ;
O'Gara, P ;
Shapira, OM ;
Treanor, P ;
Osman, A ;
Patalis, E ;
Arkin, C ;
Diamond, R ;
Babikian, V ;
Lazar, HL ;
Shemin, RJ .
ANNALS OF THORACIC SURGERY, 1998, 65 (02) :425-433
[2]   Heparin-coated circuits reduce occult myocardial damage during CPB:: a randomized, single blind clinical trial [J].
Belboul, A ;
Löfgren, C ;
Storm, C ;
Jungbeck, M .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (05) :580-586
[3]   Hemorrhage and the use of blood products after adult cardiac operations: Myths and realities [J].
Belisle, S ;
Hardy, JF .
ANNALS OF THORACIC SURGERY, 1996, 62 (06) :1908-1917
[4]   AUTOTRANSFUSION AFTER CORONARY-ARTERY BYPASS-SURGERY - IS THERE ANY BENEFIT [J].
BOUBOULIS, N ;
KARDARA, M ;
KESTEVEN, PJ ;
JAYAKRISHNAN, AG .
JOURNAL OF CARDIAC SURGERY, 1994, 9 (03) :314-321
[5]   ROLE OF FACTOR-XII IN THROMBIN GENERATION AND FIBRINOLYSIS DURING CARDIOPULMONARY BYPASS [J].
BURMAN, JF ;
CHUNG, HI ;
LANE, DA ;
PHILIPPOU, H ;
ADAMI, A ;
LINCOLN, JCR .
LANCET, 1994, 344 (8931) :1192-1193
[6]   Pericardial blood activates the extrinsic coagulation pathway during clinical cardiopulmonary bypass [J].
Chung, JH ;
Gikakis, N ;
Rao, AK ;
Drake, TA ;
Colman, RW ;
Edmunds, LH .
CIRCULATION, 1996, 93 (11) :2014-2018
[7]   Linkage between inflammation and coagulation: An update on the molecular basis of the crosstalk [J].
Cicala, C ;
Cirino, G .
LIFE SCIENCES, 1998, 62 (20) :1817-1824
[8]  
Davidson SJ, 2001, THROMB HAEMOSTASIS, V85, P195
[9]   RETRANSFUSION OF SUCTIONED BLOOD DURING CARDIOPULMONARY BYPASS IMPAIRS HEMOSTASIS [J].
DEHAAN, J ;
BOONSTRA, PW ;
MONNINK, SHJ ;
EBELS, T ;
VANOEVEREN, W .
ANNALS OF THORACIC SURGERY, 1995, 59 (04) :901-907
[10]   TISSUE-TYPE PLASMINOGEN-ACTIVATOR AND FIBRIN MONOMERS SYNERGISTICALLY CAUSE PLATELET DYSFUNCTION DURING RETRANSFUSION OF SHED BLOOD AFTER CARDIOPULMONARY BYPASS [J].
DEHAAN, J ;
SCHONBERGER, J ;
HAAN, J ;
VANOEVEREN, W ;
EIJGELAAR, A .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1993, 106 (06) :1017-1023