Industrial Raman: Providing easy, immediate, cost-effective, chemical analysis anywhere

被引:10
作者
Farquharson, S [1 ]
Smith, W [1 ]
Carangelo, R [1 ]
Brouillette, C [1 ]
机构
[1] Real Time Analyzers, E Hartford, CT 06108 USA
来源
OPTICAL ONLINE INDUSTRIAL PROCESS MONITORING | 1999年 / 3859卷
关键词
Raman spectroscopy; real-time monitoring; process control;
D O I
10.1117/12.372937
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
During the past decade Raman spectroscopy has moved out of the shadow of infrared spectroscopy and has become a routine laboratory tool for chemical analysis. This is largely due to the development of stable diode lasers, fiber optic sample probes, compact optical designs (full spectra without scanning), high quantum efficiency detectors, and personal computers with fast electronics, and associated data acquisition and analysis. These developments allow real-time (one minute or less), multi-component chemical analysis, and suggest the use of Raman spectroscopy for process monitoring and control. Single-ended fiber optic probes simplify coupling into process streams, allow remote placement of the Raman instrument from the sample point, and give Raman spectroscopy a decided advantage over infrared spectroscopy in industrial liquid and solid process applications. Indeed, more than a dozen new Raman instrument companies offering fiber optic based systems have been launched in the past five years. Notably, all of these systems employ charge coupled device detectors. And yet, only one company has successfully penetrated the industrial market. Instrument limitations cited include fluorescence interference, incomplete spectral coverage (particularly CH and OH regions), wavelength reproducibility, and long-term instrument stability. To address these limitations, Real-Time Analyzers has developed a Fourier transform Raman instrument. It employs a diode pumped Nd:YAG laser with excitation at 1064 nm and a single element, uncooled InGaAs detector, that are integrated into On-Line Technologies' proven rugged, vibration and temperature immune interferometer. Instrument design and industrial applications will be presented.
引用
收藏
页码:14 / 23
页数:10
相关论文
共 39 条
[1]   Raman and NIR spectroscopic methods for determination of total dietary fiber in cereal foods: A comparative study [J].
Archibald, DD ;
Kays, SE ;
Himmelsbach, DS ;
Barton, FE .
APPLIED SPECTROSCOPY, 1998, 52 (01) :22-31
[2]  
BURKERT P, 1983, Patent No. 4383762
[3]   FREQUENCY/WAVELENGTH CALIBRATION OF MULTIPURPOSE MULTICHANNEL RAMAN SPECTROMETERS .1. INSTRUMENTAL FACTORS AFFECTING PRECISION [J].
CARTER, DA ;
PEMBERTON, JE .
APPLIED SPECTROSCOPY, 1995, 49 (11) :1550-1560
[4]   FREQUENCY/WAVELENGTH CALIBRATION OF MULTIPURPOSE MULTICHANNEL RAMAN SPECTROMETERS .2. CALIBRATION FIT CONSIDERATIONS AND CALIBRATION STANDARDS [J].
CARTER, DA ;
THOMPSON, WR ;
TAYLOR, CE ;
PEMBERTON, JE .
APPLIED SPECTROSCOPY, 1995, 49 (11) :1561-1576
[5]  
CHASE DB, 1994, FT RAMAN SPECTROSCOP
[6]  
CLEVETT KJ, 1986, PROCESS ANAL TECHNOL
[7]  
Connes J., 1961, Rev. Opt, V40, P45
[8]   DETERMINATION OF OCTANE NUMBERS AND REID VAPOR-PRESSURE OF COMMERCIAL PETROLEUM FUELS USING FT-RAMAN SPECTROSCOPY AND PARTIAL LEAST-SQUARES REGRESSION-ANALYSIS [J].
COOPER, JB ;
WISE, KL ;
GROVES, J ;
WELCH, WT .
ANALYTICAL CHEMISTRY, 1995, 67 (22) :4096-4100
[9]  
CORDELLA PJ, 1999, SPQ 99 C E BRUNSW NJ
[10]  
DENTON MB, 1997, PHOTON SPECTRA, P96