Unconstrained and non-invasive measurement of heart-beat and respiration periods using a phonocardiographic sensor

被引:31
作者
Tanaka, S
Matsumoto, Y [1 ]
Wakimoto, K
机构
[1] Yamaguchi Prefectural Ind Technol Inst, Yamaguchi, Japan
[2] Yamaguchi Univ, Fac Engn, Yamaguchi, Japan
关键词
heart-beat; respiration; phonocardiographic sensor; unconstrained; non-invasive; home healthcare;
D O I
10.1007/BF02348132
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
With the rapid growth in the number of elderly people in the population, interest in health monitoring is increasing. Therefore the development of an unconstrained and non-invasive vital signs measurement system could be important for monitoring health status at home or in hospitals or nursing facilities. A simple system is proposed for measuring heart-beat and respiration periods for home healthcare. This was achieved with a phonocardiographic (PCG) sensor set on a water-mat or air-mat. The PCG sensor was an acceleration sensor that extracted the vibration of the mat caused by heart-beat and respiration. By calculating an auto-correlation function of the fully rectified sensor output or by local pattern matching between the rectified output and a reference signal (pre-memorised for each subject), the system measured the average and instantaneous periods of both heart-beat and respiration. Results showed that these periods were measured to a similar level of accuracy as for the electrocardiogram and thermistor respiration pickup. The comparative accuracies were within the following ranges: average heartbeat 0.19% to 0.67%, instantaneous heartbeat 0.53% to 1.15%, average respiration 0.51% to 2.17%, and instantaneous respiration 2.51% to 5.20%.
引用
收藏
页码:246 / 252
页数:7
相关论文
共 9 条
[1]  
Antoniou A., 1979, DIGITAL FILTERS ANAL
[2]   OBSERVATION OF ELECTROCARDIOGRAMS THROUGH TAP WATER [J].
ISHIJIMA, M ;
TOGAWA, T .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1989, 10 (02) :171-175
[3]   Cardiopulmonary monitoring by textile electrodes without subject-awareness of being monitored [J].
Ishijima, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (06) :685-690
[4]  
Nakazawa M, 2000, ELECTRON COMM JPN 2, V83, P1, DOI 10.1002/(SICI)1520-6432(200004)83:4<1::AID-ECJB1>3.0.CO
[5]  
2-F
[6]  
*NIH KOD CO LTD, 1998, 880600 NIH KOD CO LT
[7]  
Nishida Y., 1998, J ROBOTICS SOC JAPAN, V16, P705, DOI DOI 10.7210/JRSJ.16.705
[8]  
UOZUMI Z, 1977, JPN HEART J, V2, P426
[9]  
Watanabe H., 1999, Transactions of the Society of Instrument and Control Engineers, V35, P1012