Development of a confined wall-jet flow-through cell for simultaneous electrochemical and surface plasmon resonance applications

被引:26
作者
Bart, M [1 ]
van Os, PJHJ [1 ]
Kamp, B [1 ]
Bult, A [1 ]
van Bennekom, WP [1 ]
机构
[1] Univ Utrecht, Fac Pharmaceut Sci, Dept Biomed Anal, NL-3508 TB Utrecht, Netherlands
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2002年 / 84卷 / 2-3期
关键词
ESM surface plasmon resonance (SPR); electrochemical impedance spectroscopy (EIS); confined wall-jet flow-through cell; immunosensor; hydrodynamics; peak dispersion;
D O I
10.1016/S0925-4005(02)00013-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-through cell of the confined wall-jet type for electrochemical surface plasmon resonance (ESPR) applications has been developed. The geometrical cell volume of the electrochemical (EC) detection is adjusted to the surface plasmon resonance (SPR) cell volume by reducing the electrode diameter. An electrode diameter of 3 mrn gives the best similarity of the SPR and EC responses, using hexacyanoferrate(II) in a flow-injection analysis (FIA) setup. Further hydrodynamic characterization is done by continuous-flow analysis, The dependence of the limiting Faradaic current on the volume flow rate (phi(v)) and the spacing (b) between working and auxiliary electrode have been determined. The exponents found for phi(v) are in the range from 0.29 to 0.35 and for b in the range from -0.37 to -0.57 for typical flows (10-1000 mul min(-1)) and spacings (0.13-0.50 mm), respectively. Preliminary results of an impedimetric/liposome-enhanced SPR immunosensor for interferon-gamma (INF-gamma), based on an acetylcysteine self-assembled monolayer. show the characteristics and applicability of this new flow-through cell for ESPR research in a FIA setup. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:129 / 135
页数:7
相关论文
共 37 条
  • [1] Dynamic electrochemistry: Methodology and application
    Anderson, JL
    Coury, LA
    Leddy, J
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (18) : 4497 - 4520
  • [2] BABA A, 2001, AM CHEM SOC, V221
  • [3] Bard A. J., 1980, ELECTROCHEMICAL METH
  • [4] Capacitance measurements of antibody-antigen interactions in a flow system
    Berggren, C
    Johansson, G
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (18) : 3651 - 3657
  • [5] Berggren C, 1999, ELECTROANAL, V11, P156, DOI 10.1002/(SICI)1521-4109(199903)11:3<156::AID-ELAN156>3.0.CO
  • [6] 2-O
  • [7] Investigations of prussian blue films using surface plasmon resonance
    Brennan, CB
    Sun, LF
    Weber, SG
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (01) : 1 - 10
  • [8] Experimental data from a trace metal sensor combining surface plasmon resonance with anodic stripping voltammetry
    Chinowsky, TM
    Saban, SB
    Yee, SS
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1996, 35 (1-3) : 37 - 43
  • [9] HYDRODYNAMIC PROPERTIES AND MASS-TRANSFER CHARACTERISTICS OF ELECTROCHEMICAL FLOW-THROUGH CELLS OF THE CONFINED WALL JET TYPE
    DALHUIJSEN, AJ
    VANDERMEER, TH
    HOOGENDOORN, CJ
    HOOGVLIET, JC
    VANBENNEKOM, WP
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 182 (02) : 295 - 313
  • [10] Formation and electrochemical characterization of self-assembled monolayers of thioctic acid on polycrystalline gold electrodes in phosphate buffer pH 7.4
    Dijksma, M
    Kamp, B
    Hoogvliet, JC
    van Bennekom, WP
    [J]. LANGMUIR, 2000, 16 (08) : 3852 - 3857