Detecting microcirculatory changes in blood oxygen state with steady-state free precession imaging

被引:32
作者
Dharmakumar, Rohan [1 ]
Qi, Xiuling [1 ]
Hong, Juimiin [1 ]
Wright, Graham A. [1 ]
机构
[1] Univ Toronto, Hlth Sci Ctr, Sunnybrook & Womens Coll, Dept Med Biophys, Toronto, ON M4N 3M5, Canada
关键词
SSFP; systemic hypoxia; blood; microcirculation; oxygen;
D O I
10.1002/mrm.20911
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, it has been demonstrated that oxygen-weighted images of whole blood can be obtained with steady-state methods. In this article, based on computational and experimental models, we investigate the potential for employing this technique to monitor oxygen changes in microcirculation. Results show that oxygen-sensitive images of rabbit kidney and muscle may be obtained at high signal-to-noise ratio within a few seconds. The results also show that in steady-state free precession imaging, in addition to the exchange mechanism that generates oxygen contrast in blood, there are additional mechanisms that provide oxygen-sensitive contrast in microcirculation.
引用
收藏
页码:1372 / 1380
页数:9
相关论文
共 24 条
[1]   OXYGEN-TENSION MAPPING WITH F-19 ECHO-PLANAR MR-IMAGING OF SEQUESTERED PERFLUOROCARBON [J].
BARKER, BR ;
MASON, RP ;
BANSAL, N ;
PESHOCK, RM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (04) :595-602
[2]  
BAUER C, 1989, ANNU REV PHYSIOL, V51, P845, DOI 10.1146/annurev.physiol.51.1.845
[3]  
Bowen CV., 2005, P 13 ANN M ISMRM MIA, P119
[4]   MR CONTRAST DUE TO INTRAVASCULAR MAGNETIC-SUSCEPTIBILITY PERTURBATIONS [J].
BOXERMAN, JL ;
HAMBERG, LM ;
ROSEN, BR ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) :555-566
[5]  
Dharmakumar R, 2004, CIRCULATION, V110, P685
[6]   A novel microbubble construct for intracardiac or intravascular MR manometry: a theoretical study [J].
Dharmakumar, R ;
Plewes, DB ;
Wright, GA .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (20) :4745-4762
[7]   Oxygen-sensitive contrast in blood for steady-state free precession imaging [J].
Dharmakumar, R ;
Hong, JM ;
Brittain, JH ;
Plewes, DB ;
Wright, GA .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (03) :574-583
[8]   Vasodilator response assessment in porcine myocardium with magnetic resonance relaxometry [J].
Foltz, WD ;
Huang, H ;
Fort, S ;
Wright, GA .
CIRCULATION, 2002, 106 (21) :2714-2719
[9]   BOLD MRI MONITORING OF CHANGES IN CEREBRAL PERFUSION INDUCED BY ACETAZOLAMIDE AND HYPERCARBIA IN THE RAT [J].
GRAHAM, GD ;
ZHONG, J ;
PETROFF, OAC ;
CONSTABLE, RT ;
PRICHARD, JW ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (05) :557-560
[10]  
Haacke E M., 1999, MAGNETIC RESONANCE I, P451