Thermal effects in excimer laser trephination of the cornea

被引:12
作者
Langenbucher, A
Seitz, B
Kus, MM
Naumann, GOH
机构
关键词
D O I
10.1007/BF02343064
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Excimer laser trephination, as an alternative to mechanical trephination of the cornea in penetrating keratoplasty, is expected to reduce long-term postkeratoplasty astigmatism. Trephination with high energy densities may induce thermal epithelial alterations when metal aperture masks are used. Methods: Ninety porcine eyes fixed in an artificial anterior chamber (20 mmHg) were trephined with a 193-nm excimer laser in order to study the effect of the temperature on the cornea and the aperture mask during and after termination of the laser exposure. Energy levels tested were in the range used in patients. A pyroelectric infrared sensor connected to a PC via an analog-digital converter was used. With a high-speed sampling routine written in C++ it was possible to monitor on line the temperature in a focus 0.8 mm in diameter. Results: In donor trephination the maximum temperature increase of the metal mask was 11 K (donor tissue 6.1 K, repetition rate 30/s). During recipient trephination the maximum temperature increase of the mask was 9.4 K (7.5 K on the cornea). An increase in the repetition rate and a decrease in the rotation speed resulted in greater temperature increase of the exposed cornea or metal mask. Conclusions: Online monitoring of cornea and mask surface temperatures during excimer laser trephination is possible using high-speed sampling equipment. Appropriate adjustment of repetition rate and rotation speed may reduce thermal effects, especially in donor trephination.
引用
收藏
页码:S142 / S148
页数:7
相关论文
共 23 条
[1]   SIDE-EFFECTS IN EXCIMER CORNEAL SURGERY - CORNEAL THERMAL-GRADIENTS [J].
BENDE, T ;
SEILER, T ;
WOLLENSAK, J .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1988, 226 (03) :277-280
[2]  
Gebhart E, 1990, Fortschr Ophthalmol, V87, P229
[3]  
Koch J W, 1991, Refract Corneal Surg, V7, P214
[4]  
KRUGER RR, 1985, INVEST OPHTHALMOL VI, V26, P1455
[5]   LAMELLAR EXCIMER LASER KERATOPLASTY - REPRODUCIBLE PHOTOABLATION OF CORNEAL TISSUE - A LABORATORY STUDY [J].
KUBOTA, T ;
SEITZ, B ;
TETSUMOTO, K ;
NAUMANN, GOH .
DOCUMENTA OPHTHALMOLOGICA, 1992, 82 (03) :193-200
[6]  
KUBOTA T, 1994, JPN J OPHTHALMIC SUR, V7, P131
[7]  
Lang G K, 1989, Fortschr Ophthalmol, V86, P437
[8]  
LANG GK, 1989, OPHTHALMIC SURG LAS, V20, P262
[9]  
LANGENBUCHER A, 1994, INVEST OPHTH VIS SCI, V35, P1879
[10]   PHYSICAL PROPERTIES OF BOVINE CORNEAL COLLAGEN [J].
LEWIS, MS ;
DUBIN, MW ;
AANDAHL, VA .
EXPERIMENTAL EYE RESEARCH, 1967, 6 (01) :57-&