Theoretical framework for a dynamic cone-beam reconstruction algorithm based on a dynamic particle model

被引:50
作者
Grangeat, P [1 ]
Koenig, A [1 ]
Rodet, T [1 ]
Bonnet, S [1 ]
机构
[1] CEA, DRT, DSIS, LETI, F-38054 Grenoble 9, France
关键词
D O I
10.1088/0031-9155/47/15/304
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dynamic cone-beam reconstruction algorithms are required to reconstruct three-dimensional (3D) image sequences on dynamic 3D CT combining multi-row two-dimensional (2D) detectors and sub-second scanners. The speed-up of the rotating gantry allows one to improve the temporal resolution of the image sequence, but at the same time, it implies increase in the dose delivered during a given time period to keep constant the signal-to-noise ratio associated with each frame. The alternative solution proposed in this paper is to process data acquisition on several half-turns in order to reduce the dose delivered per rotation with the same signal-to-noise ratio. In order to compensate for time evolution and motion artefacts, we propose to use a dynamic particle model to describe the object evolution during the scan. In this article, we first introduce the dynamic particle model and the dynamic CT acquisition model. Then, we explain the principle of the proposed dynamic cone-beam reconstruction algorithm. Lastly, we present preliminary results on simulated data.
引用
收藏
页码:2611 / 2625
页数:15
相关论文
共 17 条
  • [1] Bayesian motion estimation for temporally recursive noise reduction in X-ray fluoroscopy
    Aach, T
    Kunz, D
    [J]. PHILIPS JOURNAL OF RESEARCH, 1998, 51 (02) : 231 - 251
  • [2] CLARYSSE P, 2001, GRETSI 01 TOUL 10 13
  • [3] DEFRISE M, 2002, TOMOGRAPHIE, P53
  • [4] Sindbad: From CAD model to synthetic radiographs
    Gliere, A
    [J]. REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 17A AND 17B, 1998, : 387 - 394
  • [5] Grangeat P, 2001, ENCY COMP S, V44, P167
  • [6] 3D cone-beam CT reconstruction for circular trajectories
    Grass, M
    Köhler, T
    Proksa, R
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (02) : 329 - 347
  • [7] Analysis of the temporal response of computed tomography fluoroscopy
    Hsieh, J
    [J]. MEDICAL PHYSICS, 1997, 24 (05) : 665 - 675
  • [8] Koenig A, 2002, CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, P521
  • [9] LOMBARDO JC, 1996, THESIS U J FOURIER
  • [10] Adaptive Motion-Compensated Filtering of Noisy Image Sequences
    Oezkan, Mehmet K.
    Sezan, Ibrahim
    Tekalp, A. Murat
    [J]. IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS FOR VIDEO TECHNOLOGY, 1993, 3 (04) : 277 - 290