Smart mobile affinity matrix for microfluidic immunoassays

被引:67
作者
Malmstadt, N [1 ]
Hoffman, AS [1 ]
Stayton, PS [1 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
来源
LAB ON A CHIP | 2004年 / 4卷 / 04期
关键词
D O I
10.1039/b315394k
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
There is a current need for simple methods for immobilizing biomolecules within microfluidic channels. Here, a technique is reported for reversibly immobilizing immunoassay components in a channel zone that can be simply controlled by integrated heating elements. Latex beads were modified with the temperature-responsive polymer poly(N-isopropylacrylamide) (PNIPAAm) and co-modified with biotinylated poly( ethylene glycol) ( PEG). PNIPAAm undergoes a hydrophilic-to-hydrophobic transition when the temperature is raised above the lower critical solution temperature (LCST) (similar to28 degreesC in the solutions used here). This reversible transition drives the aggregation and dis-aggregation of the modified beads in heated zones within poly( ethylene terephthalate) (PET) microchannels. Biotinylated monoclonal antibodies for the drug digoxin were bound via streptavidin to the biotin-PEG-coated beads. These antibody-functionalized beads were then reversibly immobilized by aggregation and hydrophobic adhesion to the surface of PET microfluidic channels in response to a thermal stimulus. The antibodies on the beads immobilized in the channel were shown to bind digoxin and a competitor fluorescent ligand from a flow stream in a quantitative competitive assay format that reported the digoxin concentration. The antibodies could be replenished for each immunoassay trial, using the reversible, temperature-controlled immobilization process. This technique allows reagent immobilization immediately prior to an analytical procedure, following the removal of previously utilized beads, guaranteeing fresh and active immobilized biomolecules. Furthermore, it provides a simple approach to multiplexing through the simultaneous or sequential injection of different antibody-coated bead species, potentially at multiple sites in the integrated device channels.
引用
收藏
页码:412 / 415
页数:4
相关论文
共 34 条
[1]   Micromachined flow-through filter-chamber for chemical reactions on beads [J].
Andersson, H ;
van der Wijngaart, W ;
Enoksson, P ;
Stemme, G .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 67 (1-2) :203-208
[2]   Biomolecular recognition on well-characterized beads packed in microfluidic channels [J].
Buranda, T ;
Huang, JM ;
Perez-Luna, VH ;
Schreyer, B ;
Sklar, LA ;
Lopez, GP .
ANALYTICAL CHEMISTRY, 2002, 74 (05) :1149-+
[3]   An integrated fritless column for on-chip capillary electrochromatography with conventional stationary phases [J].
Ceriotti, L ;
de Rooij, NF ;
Verpoorte, E .
ANALYTICAL CHEMISTRY, 2002, 74 (03) :639-647
[4]   SITE-DIRECTED MUTAGENESIS STUDIES OF THE HIGH-AFFINITY STREPTAVIDIN-BIOTIN COMPLEX - CONTRIBUTIONS OF TRYPTOPHAN RESIDUE-79, RESIDUE-108, AND RESIDUE-120 [J].
CHILKOTI, A ;
TAN, PH ;
STAYTON, PS .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (05) :1754-1758
[5]   Protein arrays: The current state-of-the-art [J].
Cutler, P .
PROTEOMICS, 2003, 3 (01) :3-18
[6]   Synthesis and purification of thermally sensitive oligomer-enzyme conjugates of poly(N-isopropylacrylamide)-trypsin [J].
Ding, ZL ;
Chen, GH ;
Hoffman, AS .
BIOCONJUGATE CHEMISTRY, 1996, 7 (01) :121-125
[7]   Electrokinetically driven microfluidic chips with surface-modified chambers for heterogeneous immunoassays [J].
Dodge, A ;
Fluri, K ;
Verpoorte, E ;
de Rooij, NF .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3400-3409
[8]  
Ekström S, 2002, PROTEOMICS, V2, P413, DOI 10.1002/1615-9861(200204)2:4<413::AID-PROT413>3.0.CO
[9]  
2-1
[10]   Electroosmosis- and pressure-driven chromatography in chips using continuous beds [J].
Ericson, C ;
Holm, J ;
Ericson, T ;
Hjertén, S .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :81-87