Sustained local delivery of dexamethasone by a novel intravascular eluting stent to prevent restenosis in the porcine coronary injury model

被引:268
作者
Lincoff, AM
Furst, JG
Ellis, SG
Tuch, RJ
Topol, EJ
机构
[1] CLEVELAND CLIN FDN,JOSEPH J JACOBS CTR THROMBOSIS & VASC BIOL,CLEVELAND,OH 44195
[2] MEDTRONIC INC,MINNEAPOLIS,MN
关键词
D O I
10.1016/S0735-1097(96)00584-0
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Objectives. This study sought to assess the feasibility, safety and efficacy of sustained intracoronary delivery of dexamethasone by a novel polymer-coated eluting stent, Background. Development of techniques to provide sustained local drug delivery has focused on polymers as matrices for drug incorporation and elution, Methods. A tantalum wire stent was coated with dexamethasone (0.8 mg) suspended in a matrix of either low (similar to 80 kD) or high (similar to 321 kD) molecular weight poly-L-lactic acid (PLLA [0.4 mg]), Uncoated stents, stents coated with PLLA or stents coated with dexamethasone in PLLA were overexpanded by 30% to the normal vessel diameter in the coronary arteries of juvenile farm pigs, Animals were euthanized 28 days later, and neointimal thicknesses were measured, Additional pigs underwent placement of stents coated with high molecular weight PLLA-dexamethasone for assessment of arterial tissue and serum concentrations of dexamethasone at 1 h and 1, 2, 10 and 28 days after stent implantation. Results. In vitro dexamethasone release occurred over the first 6 days, Stents coated with low molecular weight PLLA produced an intense inflammatory neointimal response, Stents utilizing the high molecular weight PLLA were well tolerated within the coronary vessel during the 28-day experiment, However, dexamethasone did not decrease neointimal hyperplasia, Dexamethasone concentrations in the arterial tissue were similar to 300,000-fold higher than those in the serum 24 h after stent implantation, remaining similar to 3,000-fold higher at 28 days, Conclusions. The eluting stent utilizing high molecular weight PLLA appeared to be a well tolerated and effective means of providing sustained, site-specific drug delivery to the porcine coronary artery wall for at least 28 days. (C) 1997 by the American College of Cardiology.
引用
收藏
页码:808 / 816
页数:9
相关论文
共 39 条
[1]
DECREASED PLATELET DEPOSITION AND SMOOTH-MUSCLE CELL-PROLIFERATION AFTER INTRAMURAL HEPARIN DELIVERY WITH HYDROGEL-COATED BALLOONS [J].
AZRIN, MA ;
MITCHEL, JF ;
FRAM, DB ;
PEDERSEN, CA ;
CARTUN, RW ;
BARRY, JJ ;
BOW, LM ;
WATERS, DD ;
MCKAY, RG .
CIRCULATION, 1994, 90 (01) :433-441
[2]
AZRIN MA, 1993, CIRCULATION, V88, P310
[3]
BERK BC, 1991, J AM COLL CARDIOL, V17, pB111
[4]
RESORBABLE POLY(L-LACTIDE) PLATES AND SCREWS FOR THE FIXATION OF ZYGOMATIC FRACTURES [J].
BOS, RRM ;
BOERING, G ;
ROZEMA, FR ;
LEENSLAG, JW .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1987, 45 (09) :751-753
[5]
CAMENZIND E, 1995, CIRCULATION S1, V92, P785
[6]
INVIVO DEGRADATION OF POLY(LACTIC ACID) OF DIFFERENT MOLECULAR-WEIGHTS [J].
CHAWLA, AS ;
CHANG, TMS .
BIOMATERIALS MEDICAL DEVICES AND ARTIFICIAL ORGANS, 1985, 13 (3-4) :153-162
[7]
EFFECT OF LOCAL-DELIVERY OF HEPARIN AND METHOTREXATE ON NEOINTIMAL PROLIFERATION IN STENTED PORCINE CORONARY-ARTERIES [J].
COX, DA ;
ANDERSON, PG ;
ROUBIN, GS ;
CHOU, CY ;
AGRAWAL, SK ;
CAVENDER, JB .
CORONARY ARTERY DISEASE, 1992, 3 (03) :237-248
[8]
CONTRASTING EFFECTS OF THE INTERMITTENT AND CONTINUOUS ADMINISTRATION OF HEPARIN IN EXPERIMENTAL RESTENOSIS [J].
EDELMAN, ER ;
KARNOVSKY, MJ .
CIRCULATION, 1994, 89 (02) :770-776
[9]
NEW APPROACH FOR LOCAL INTRAVASCULAR DRUG-DELIVERY - IONTOPHORETIC BALLOON [J].
FERNANDEZORTIZ, A ;
MEYER, BJ ;
MAILHAC, A ;
FALK, E ;
BADIMON, L ;
FALLEN, JT ;
FUSTER, V ;
CHESEBRO, JH ;
BADIMON, JJ .
CIRCULATION, 1994, 89 (04) :1518-1522
[10]