Inter- and intra-measurer error in the measurement of Reimers' hip migration percentage

被引:68
作者
Faraj, S [1 ]
Atherton, WG [1 ]
Stott, NS [1 ]
机构
[1] Starship Childrens Hosp, Auckland, New Zealand
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2004年 / 86B卷 / 03期
关键词
D O I
10.1302/0301-620X.86B3.14094
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Reimers' hip migration percentage is commonly used to document the extent of subluxation of the hip in children with spasticity. In this study, two measurers, with six months paediatric orthopaedic experience, measured the migration percentage on 44 pelvic radiographs of children with cerebral palsy, aged between two and eight years. Unknown to the measurers, each radiograph was duplicated, giving 22 non-identical radiographs (44 hips) which were measured twice at time 0 and twice six weeks later. The intra-measurer, intra-sessional absolute differences between the first and second measurements ranged from 0% to 23%, with median values of 2.5% to 3.6%. The intra-sessional median absolute differences were not statistically different between the two measurers and measuring sessions (p = 0.42, Kruskal-Wallis test). The inter-sessional absolute differences for measurements made by the same measurers ranged from 0% to 18% with a median absolute difference of 1.7% to 3.2%. Overall, only 5% of the intra-measurer measurement differences, within and between sessions, were above 13%. Repeated measurements by one measurer over time must, therefore, vary by more than 13% in order to be 95% confident of a true change. The inter-measurer error was higher with median absolute differences between the two measurers' measurements of the same hip of 3.25% to 5% (0% to 26%) and a 95(th) upper confidence interval of 21% to 23%. Averaging the four separate measurements over the two sessions reduced the inter-measurer error to a median absolute difference of 2.8%, but did not improve the 95(th) upper confidence interval, which measured 22.4%. Such inter-measurer errors may be clinically unacceptable.
引用
收藏
页码:434 / 437
页数:4
相关论文
共 12 条
[1]
RELIABILITY OF RADIOLOGICAL MEASUREMENTS IN THE ASSESSMENT OF THE CHILDS HIP [J].
BROUGHTON, NS ;
BROUGHAM, DI ;
COLE, WG ;
MENELAUS, MB .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (01) :6-8
[2]
Inaccuracy of the migration percentage and center-edge angle in predicting femoral head displacement in cerebral palsy [J].
Brunner, R ;
Robb, JE .
JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 1996, 5 (04) :239-241
[3]
Predicting the outcome of adductor tenotomy [J].
Cottalorda, J ;
Gautheron, V ;
Metton, G ;
Charmet, E ;
Maatougui, K ;
Chavrier, Y .
INTERNATIONAL ORTHOPAEDICS, 1998, 22 (06) :374-379
[4]
EKLOF O, 1988, ACTA RADIOL, V29, P363
[5]
CHANGES IN HIP MIGRATION AFTER SELECTIVE DORSAL RHIZOTOMY FOR SPASTIC QUADRIPLEGIA IN CEREBRAL-PALSY [J].
HEIM, RC ;
PARK, TS ;
VOGLER, GP ;
KAUFMAN, BA ;
NOETZEL, MJ ;
ORTMAN, MR .
JOURNAL OF NEUROSURGERY, 1995, 82 (04) :567-571
[6]
MILLER F, 1995, DEV MED CHILD NEUROL, V37, P449
[7]
PREVENTION OF HIP DISLOCATION IN CEREBRAL-PALSY BY EARLY PSOAS AND ADDUCTORS TENOTOMIES [J].
ONIMUS, M ;
ALLAMEL, G ;
MANZONE, P ;
LAURAIN, JM .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1991, 11 (04) :432-435
[8]
EFFECTS OF SELECTIVE DORSAL RHIZOTOMY FOR SPASTIC DIPLEGIA ON HIP MIGRATION IN CEREBRAL-PALSY [J].
PARK, TS ;
VOGLER, GP ;
PHILLIPS, LH ;
KAUFMAN, BA ;
ORTMAN, MR ;
MCCLURE, SM ;
GAFFNEY, PE .
PEDIATRIC NEUROSURGERY, 1994, 20 (01) :43-49
[9]
Hip displacement in spastic cerebral palsy: Repeatability of radiologic measurement [J].
Parrott, J ;
Boyd, RN ;
Dobson, F ;
Lancaster, A ;
Love, S ;
Oates, J ;
Wolfe, R ;
Nattrass, GR ;
Graham, HK .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2002, 22 (05) :660-667
[10]
Reimers J, 1980, Acta Orthop Scand Suppl, V184, P1