Ultrafast MR imaging of the fetus

被引:86
作者
Kubik-Huch, RA
Huisman, TAGM
Wisser, J
Gottstein-Aalame, N
Debatin, JF
Seifert, B
Ladd, ME
Stallmach, T
Marincek, B
机构
[1] Univ Zurich Hosp, Dept Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Dept Obstet, CH-8091 Zurich, Switzerland
[3] Univ Zurich, Div Biostat, CH-8006 Zurich, Switzerland
[4] Univ Zurich Hosp, Dept Pathol, CH-8091 Zurich, Switzerland
关键词
D O I
10.2214/ajr.174.6.1741599
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. We examined the capability of ultrafast single-shot fast spin-echo imaging to assess different fetal organ systems compared with prenatal sonography, using autopsy or postpartum imaging as a standard of reference. SUBJECTS AND METHODS. Thirty women with complicated pregnancies (mean age of gestation, 190 +/- 54 days) underwent T2-weighted ultrafast MR imaging. MR images were analyzed with regard to diagnostic confidence in assessing abnormalities of fetal organ systems, and data were correlated with postpartum findings or necropsy. Results were compared with those of prenatal sonography, RESULTS. Using receiver operating characteristic curve analysis, diagnostic confidence of MR imaging was best for assessing the brain (area under the curve [A(z)] = 0.96) and spinal canal (A(z) = 1.0), uteroplacental unit (A(z) = 0.93), and lungs (A(z) = 0.91), Results for the heart (A(z) = 0.63) and extremities (A(z) = 0.77) were significantly lower than that of other organs (p < 0.001), Diagnostic accuracy increased with gestational age. No statistically significant difference between sonography and MR imaging was found for the detection of abnormality in any organ system. In three fetuses, MR imaging was superior to sonography in characterizing cerebral abnormalities. MR imaging was inferior to sonography in characterizing abnormalities of the heart and extremities. CONCLUSION, Our results indicate that ultrafast MR imaging can be used for in vivo fetal imaging, especially in assessing cerebral abnormalities. However, MR imaging should be restricted to situations in which sonographic findings are ambiguous or impaired.
引用
收藏
页码:1599 / 1606
页数:8
相关论文
共 24 条
[1]   ESTIMATION OF FETAL LUNG-VOLUME USING ECHO-PLANAR MAGNETIC-RESONANCE-IMAGING [J].
BAKER, PN ;
JOHNSON, IR ;
GOWLAND, PA ;
FREEMAN, A ;
ADAMS, V ;
MANSFIELD, P .
OBSTETRICS AND GYNECOLOGY, 1994, 83 (06) :951-954
[2]  
BAKER PN, 1994, AM J OBSTET GYNECOL, V170, P32
[3]   Magnetic resonance imaging of the brain of premature infants [J].
Battin, M ;
Maalouf, EF ;
Counsell, S ;
Herilhy, AH ;
Edwards, AD .
LANCET, 1997, 349 (9067) :1741-1741
[4]   NUCLEAR MAGNETIC-RESONANCE (NMR) INVIVO STUDIES - KNOWN THRESHOLDS FOR HEALTH-EFFECTS [J].
BUDINGER, TF .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (06) :800-811
[5]  
CARRINGTON B, 1991, MRI PELVIS, P37
[6]   PRENATAL-DIAGNOSIS OF FETAL CEREBRAL ABNORMALITIES BY ULTRASONOGRAPHY AND MAGNETIC-RESONANCE-IMAGING [J].
DERCOLE, C ;
GIRARD, N ;
BOUBLI, L ;
POTIER, A ;
CHAGNON, C ;
RAYBAUD, C ;
BLANC, B .
EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1993, 50 (03) :177-184
[7]  
Duncan KR, 1996, BRIT J HOSP MED, V55, P178
[8]   FAST-SCAN MAGNETIC-RESONANCE-IMAGING IN FETAL VISUALIZATION [J].
GARDEN, AS ;
GRIFFITHS, RD ;
WEINDLING, AM ;
MARTIN, PA .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1991, 164 (05) :1190-1196
[9]   MIDGESTATIONAL EXPOSURE OF PREGNANT BALB/C MICE TO MAGNETIC-RESONANCE IMAGING CONDITIONS [J].
HEINRICHS, WL ;
FONG, P ;
FLANNERY, M ;
HEINRICHS, SC ;
CROOKS, LE ;
SPINDLE, A ;
PEDERSEN, RA .
MAGNETIC RESONANCE IMAGING, 1988, 6 (03) :305-313
[10]   RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR [J].
HENNIG, J ;
NAUERTH, A ;
FRIEDBURG, H .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :823-833