Calibration of a subcutaneous amperometric glucose sensor - Part 1. Effect of measurement uncertainties on the determination of sensor sensitivity and background current

被引:45
作者
Choleau, C
Klein, JC
Reach, G
Aussedat, B
Demaria-Pesce, V
Wilson, GS
Gifford, R
Ward, WK
机构
[1] Hop Hotel Dieu, Dept Diabet, INSERM, U341, F-75004 Paris, France
[2] Ecole Mines, Ctr Math Morphol, Fontainebleau, France
[3] Univ Kansas, Dept Chem, Lawrence, KS 66045 USA
[4] Natl Appl Sci, Portland, OR 97224 USA
关键词
glucose sensor; calibration; subcutaneous tissue; type; 1; diabetes;
D O I
10.1016/S0956-5663(01)00306-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The calibration of a continuous glucose monitoring system, i.e. the transformation of the signal I(t) generated by the glucose sensor at time (t) into an estimation of glucose concentration G(t), represents a key issue. The two-point calibration procedure consists of the determination of a sensor sensitivity S and of a background current I-o by plotting two values of the sensor signal versus the concomitant blood glucose concentrations. The estimation of G(t) is subsequently given by G(t) = (I(t)-I-o)/S. A glucose sensor was implanted in the subcutaneous tissue of nine type 1 diabetic patients during 3 (n = 2) and 7 days (n = 7). For each individual trial, S and I-o were determined by taking into account the values of two sets of sensor output and blood glucose concentration distant by at least I h, the procedure being repeated for each consecutive set of values. S and I-o were found to be negatively correlated, the value of I-o being sometimes negative. Theoretical analysis demonstrates that this phenomenon can be explained by the effect of measurement uncertainties on the determination of capillary glucose concentration and of sensor output. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:641 / 646
页数:6
相关论文
共 7 条
  • [1] A user-friendly method for calibrating a subcutaneous glucose sensor-based hypoglycaemic alarm
    Aussedat, B
    Thome-Duret, V
    Reach, G
    Lemmonier, F
    Klein, JC
    Hu, Y
    Wilson, GS
    [J]. BIOSENSORS & BIOELECTRONICS, 1997, 12 (11) : 1061 - 1071
  • [2] Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring
    Aussedat, B
    Dupire-Angel, M
    Gifford, R
    Klein, JC
    Wilson, GS
    Reach, G
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2000, 278 (04): : E716 - E728
  • [3] ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
    CLARK, LC
    LYONS, C
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) : 29 - &
  • [4] REACH G, 1992, Analytical Chemistry, V64, P381
  • [5] ThomeDuret V, 1996, DIABETES METAB, V22, P174
  • [6] VELHO G, 1988, DIABETES NUTR METAB, V3, P227
  • [7] VONWOEDTKE T, 1989, BIOMED BIOCHIM ACTA, V48, P943