Pneumoperitoneum: Its alternatives

被引:4
作者
Olvera, D
Gomez, JR
机构
[1] Department of Surgery, Hospital de Mexico, Mexico, D.F.
[2] Hospital de México, México, D.F. 11800, Agrarismo 208-601 A, Col. Escandon
关键词
laparoscopy; pneumoperitoneum; trocars; Veress needle;
D O I
10.1097/00019509-199708000-00015
中图分类号
R61 [外科手术学];
学科分类号
摘要
The purpose of this study was to determine the advantages and disadvantages of several techniques for performing the pneumoperitoneum. We studied 75 patients divided into three groups of 25 each. In the first group, we used the Veress needle technique in the umbilicus. In the second group, the insertion was in the upper left quadrant, and in the third group the insertion was direct with a disposable trocar in the umbilicus without pneumoperitoneum. In the first group, we made 32 attempts, and the time varied from 8 to 35 min. In the second group we made 28 attempts and the time was from 3 to 6 min. In both we had complications. In the third group, we made 25 direct insertions without complications, and the time was from 45 s to 3 min.
引用
收藏
页码:332 / 334
页数:3
相关论文
共 23 条
[1]  
BALLEM RV, 1993, SURG LAPAROSC ENDOSC, V3, P42
[2]  
BARGATTA L, 1990, J REPROD MED, V35, P891
[3]  
BIOJO RG, 1995, SURG LAPAROSC ENDOSC, V5, P105
[4]  
COPELAND C, 1983, OBSTET GYNECOL, V62, P655
[5]  
CRIST DW, 1993, SURG CLIN N AM, V73, P265
[6]  
DINGFELDER JR, 1978, J REPROD MED, V21, P45
[7]   FROM MICROSURGERY TO LAPAROSCOPIC SURGERY - A PROGRESS [J].
GOMEL, V .
FERTILITY AND STERILITY, 1995, 63 (03) :464-468
[8]   MODIFIED INSTRUMENT AND METHOD FOR LAPAROSCOPY [J].
HASSAON, HM .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1971, 110 (06) :886-&
[9]  
HASSON HM, 1990, MANUAL ENDOSCOPY, P23
[10]  
JARRETT JC, 1990, OBSTET GYNECOL, V75, P725