OBJECTIVE. This study prospectively evaluated a computer-aided detection (CAD) device used with diagnostic and screening mammography by assessing cancers detected; tumor sizes, histology, and stage; positive predictive value (PPV) of biopsy recommendation; and recall rates before and after CAD introduction. SUBJECTS AND METHODS. Interpretations of 9,520 consecutive mammograms were recorded without and then with CAD for a 28-month period. Cancer detections based on initial radiologist review and additional detections based on CAD findings were noted. Recall rates, tumor size and histology, and PPV of biopsy recommendation before and after the introduction of CAD were compared. RESULTS. Cancers detected only with CAD assistance were 9.6% of all cancers (10 of 104); screening-detected cancers increased 13.3% with CAD assistance (four in addition to 30 screening-detected cancers). The 95% one-sided confidence boundary using binomial distribution is consistent with at least 5.3% for all cancers and 5.1% for nonpalpable cancers. The greatest impact was on ductal carcinoma in situ, for which CAD increased cancer detection by 14.2% (three added to 21). Similar percentages of cancers were detected only with CAD assistance in both screening (11.4%; 4 of 35) and diagnostic (9.5%; six of 63) studies. Additional cancers were detected using CAD in patients with implants and previous lumpectomy. The additional cancers detected with CAD were smaller (p = 0.01 for all cancers, p = 0.03 for nonpalpable invasive cancer). The screening recall rate increased from 6.2% to 7.8% after CAD, with a decrease in the biopsy rate and a nonsignificant increase in the biopsy PPV from 21.9% to 26.3%. CONCLUSION. CAD resulted in detection of more cancers in screening and diagnostic patients, with an increased recall rate but no deterioration in PPV of biopsy. Additional cancers detected were significantly smaller.
引用
收藏
页码:20 / 28
页数:9
相关论文
共 20 条
[1]   Computer-aided detection with screening mammography in a university hospital setting [J].
Birdwell, RL ;
Bandodkar, P ;
Ikeda, DM .
RADIOLOGY, 2005, 236 (02) :451-457
[2]   Mammographic characteristics of 115 missed cancers later detected with screening mammography and the potential utility of computer-aided detection [J].
Birdwell, RL ;
Ikeda, DM ;
O'Shaughnessy, KF ;
Sickles, EA .
RADIOLOGY, 2001, 219 (01) :192-202
[3]   Improvement in sensitivity of screening mammography with computer-aided detection: A multiinstitutional trial [J].
Brem, RF ;
Baum, J ;
Lechner, M ;
Kaplan, S ;
Souders, S ;
Naul, LG ;
Hoffmeister, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (03) :687-693
[4]  
Burhenne LJW, 2000, RADIOLOGY, V215, P554
[5]   Computer-aided detection in diagnostic mammography: Detection of clinically unsuspected cancers [J].
Butler, SA ;
Gabbay, RJ ;
Kass, DA ;
Siedler, DE ;
O'Shaughnessy, KF ;
Castellino, RA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (05) :1511-1515
[6]   Comparison of standard reading and computer aided detection (CAD) on a national proficiency test of screening mammography [J].
Ciatto, S ;
Del Turco, MR ;
Risso, G ;
Catarzi, S ;
Bonardi, R ;
Viterbo, V ;
Gnutti, P ;
Guglielmoni, B ;
Pinelli, L ;
Pandiscia, A ;
Navarra, F ;
Lauria, A ;
Palmiero, R ;
Indovina, PL .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 (02) :135-138
[7]   Impact of computer-aided detection in a regional screening mammography program [J].
Cupples, TE ;
Cunningham, JE ;
Reynolds, JC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (04) :944-950
[8]   Invasive lobular carcinoma of the breast: Mammographic characteristics and computer-aided detection [J].
Evans, WP ;
Burhenne, LJW ;
Laurie, L ;
O'Shaughnessy, KF ;
Castellino, RA .
RADIOLOGY, 2002, 225 (01) :182-189
[9]   Changes in breast cancer detection and mammography recall rates after the introduction of a computer-aided detection system [J].
Feig, SA ;
Sickles, EA ;
Evans, WP ;
Linver, MN .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2004, 96 (16) :1260-1261
[10]   Screening mammography with computer-aided detection: Prospective study of 12,860 patients in a community breast center [J].
Freer, TW ;
Ulissey, MJ .
RADIOLOGY, 2001, 220 (03) :781-786