Comparison between spectral analysis and the phenylephrine method for the assessment of baroreflex sensitivity in chronic heart failure

被引:30
作者
Colombo, R
Mazzuero, G
Spinatonda, G
Lanfranchi, P
Giannuzzi, P
Ponikowski, P
Coats, AJS
Minuco, G
机构
[1] Fondaz Salvatore Maugeri, IRCCS, Serv Bioengn, I-28010 Veruno, NO, Italy
[2] Div Cardiol, Veruno, NO, Italy
[3] Univ London Imperial Coll Sci Technol & Med, Natl Heart & Lung Inst, Dept Cardiac Med, London, England
关键词
baroreceptor reflex sensitivity; heart failure; heart rate variability; spectral analysis;
D O I
10.1042/CS19990035
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Baroreflex sensitivity assessed by means of the phenylephrine test plays a prognostic role in patients with previous myocardial infarction, but the need for drug injection limits the use of this technique. Recently, several non-invasive methods based on spectral analysis of systolic arterial pressure and heart period have been proposed, but their agreement with the phenylephrine test has not been investigated in patients with heart failure. The two methods (phenylephrine test and spectral analysis) were compared in a group of 49 patients with chronic congestive heart failure both at rest and during controlled breathing. The linear correlation and the limits of agreement between the phenylephrine test slope and the alpha-index [alpha(c); corrected by the coherence function between the interbeat interval (RR interval) and systolic arterial pressure] were evaluated. Only 16 patients had a measurable alpha-index at rest in both the low-frequency (LF) and high-frequency (HF) bands; the alpha(c)-index allowed measurements in all patients. It correlated moderately with the phenylephrine test slope at rest (r = 0.71 and P < 0.001 in LF; r = 0.57 and P < 0.001 in HF) and during controlled breathing (r = 0.51 and P < 0.001 in LF; r = 0.63 and P < 0.001 in HF). Multivariate regression analysis showed that only alpha(c)LF during rest and alpha(c)HF during controlled breathing contributed significantly to baroreflex gain estimation. However, the agreement between methods was weak; the normalized limits of agreement and bias were - 162 to 243% (0.46 ms/mmHg) for alpha(c)LF and - 185 to 151% (-0.99 ms/mmHg) for alpha(c)HF. Thus the comparison between baroreflex sensitivity measurements obtained by the phenylephrine test and spectral analysis showed a moderate correlation between the two methods; however, despite the linear association, a consistent lack of agreement between the two techniques was found. Because both systematic and random factors contribute to the difference, these two techniques cannot be considered as alternatives for the assessment of heart failure.
引用
收藏
页码:503 / 513
页数:11
相关论文
共 38 条
  • [1] HEMODYNAMIC REGULATION - INVESTIGATION BY SPECTRAL-ANALYSIS
    AKSELROD, S
    GORDON, D
    MADWED, JB
    SNIDMAN, NC
    SHANNON, DC
    COHEN, RJ
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1985, 249 (04): : H867 - H875
  • [2] Akselrod S., 1985, AM J PHYSIOL, V249, pH867, DOI DOI 10.1152/AJPHEART.1985.249.4.H867
  • [3] CARDIOVASCULAR VARIABILITY SIGNALS - TOWARDS THE IDENTIFICATION OF A CLOSED-LOOP MODEL OF THE NEURAL CONTROL MECHANISMS
    BASELLI, G
    CERUTTI, S
    CIVARDI, S
    MALLIANI, A
    PAGANI, M
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (12) : 1033 - 1046
  • [4] COMPARISON OF BAROREFLEX SENSITIVITY AND HEART PERIOD VARIABILITY AFTER MYOCARDIAL-INFARCTION
    BIGGER, JT
    LAROVERE, MT
    STEINMAN, RC
    FLEISS, JL
    ROTTMAN, JN
    ROLNITZKY, LM
    SCHWARTZ, PJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (06) : 1511 - 1518
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] CHEYNE-STOKES BREATHING - INSTABILITY IN PHYSIOLOGIC CONTROL
    CHERNIACK, NS
    LONGOBARDO, GS
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1973, 288 (18) : 952 - 957
  • [7] Do alpha-index and phenylephrine test provide similar measurements of baroreflex sensitivity in cardiac patients with chronic heart failure?
    Colombo, R
    Mazzuero, G
    Lanfranchi, P
    Spinatonda, G
    Minuco, G
    Giannuzzi, P
    [J]. COMPUTERS IN CARDIOLOGY 1996, 1996, : 89 - 92
  • [8] COLOMBO R, 1989, COMP CARDIOL, P475
  • [9] DEBOER RW, 1986, NEURAL MECHANISMS CA, V5, P303
  • [10] DEBOER RW, 1987, AM J PHYSIOL, V253, pH680