k-space interpretation of the Rose Model:: Noise limitation on the detectable resolution in MRI

被引:28
作者
Watts, R [1 ]
Wang, Y [1 ]
机构
[1] Cornell Univ, Weill Med Coll, Dept Radiol, New York, NY USA
关键词
k-space sampling; noise limited resolution; signal-to-noise ratio (SNR); Rose Model;
D O I
10.1002/mrm.10220
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Noise limitation on the detected spatial resolution, described by the Rose Model, is well known in X-ray imaging and routinely used in designing X-ray imaging protocols. The purpose of this article is to revisit the Rose Model in the context of Mill where image data are acquired in the spatial frequency domain. A k-space signal-to-noise ratio (kSNR) is introduced to measure the relative signal and noise powers in a circular annulus in k-space. It is found that the kSNR diminishes rapidly with k-space radius. The Rose criterion that the voxel SNR similar to4 is translated to kSNR cutoff values was tested using theoretical derivation and experimental histogram analysis. Experiments demonstrate that data acquisition beyond this cutoff k-space radius adds little or no information to the image. In order to reduce the noise limit on spatial resolution, the signal strength must be improved through means such as increasing the coil sensitivity, contrast enhancement, and signal averaging. This finding implies that the optimal k-space volume to be sampled or the optimal scan time in MRI should be matched to the relative SNR level. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:550 / 554
页数:5
相关论文
共 11 条
[1]   The Rose model, revisited [J].
Burgess, AE .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1999, 16 (03) :633-646
[2]   THE INTRINSIC SIGNAL-TO-NOISE RATIO IN NMR IMAGING [J].
EDELSTEIN, WA ;
GLOVER, GH ;
HARDY, CJ ;
REDINGTON, RW .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (04) :604-618
[3]   THE INFORMATION-CONTENT OF MR IMAGES [J].
FUDERER, M .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (04) :368-380
[4]   THE RICIAN DISTRIBUTION OF NOISY MRI DATA [J].
GUDBJARTSSON, H ;
PATZ, S .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) :910-914
[5]  
Haacke E. M., 1999, MAGNETIC RESONANCE I
[6]  
HEID O, 1997, P ISMRM 5 SCI M VANC, P254
[7]   MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES [J].
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :232-233
[8]  
PELC NJ, 1998, P ISMRM 6 ANN M SYDN, P254
[9]  
Rose A., 1973, Vision: Human and Electronic. Optical Physics and Engineering
[10]   METHODS FOR EVALUATION OF DIAGNOSTIC-IMAGING INSTRUMENTATION [J].
SHOSA, D ;
KAUFMAN, L .
PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (01) :101-112