Left ventricular systolic unloading and augmentation of intracoronary pressure and Doppler flow during enhanced external counterpulsation

被引:191
作者
Michaels, AD [1 ]
Accad, M [1 ]
Ports, TA [1 ]
Grossman, W [1 ]
机构
[1] Univ Calif San Francisco, Med Ctr, Div Cardiol, Dept Med, San Francisco, CA 94143 USA
关键词
hemodynamics; cardiovascular diseases; catheterization; blood flow; blood pressure;
D O I
10.1161/01.CIR.0000028336.95629.B0
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background-Enhanced external counterpulsation (EECP) is a noninvasive, pneumatic technique that provides beneficial effects for patients with chronic, symptomatic angina pectoris. However, the physiological effects of EECP have not been studied directly. We examined intracoronary and left ventricular hemodynamics in the cardiac catheterization laboratory during EECP. Methods and Results-Ten patients referred for diagnostic evaluation underwent left heart catheterization and coronary angiography from the radial artery. At baseline and then during EECP, central aortic pressure, intracoronary pressure, and intracoronary Doppler flow velocity were measured using a coronary catheter, a sensor-tipped high-fidelity pressure guidewire, and a Doppler flow guidewire, respectively. Similar to changes in aortic pressure, EECP resulted in a dramatic increase in diastolic (71 +/- 10 mm Hg at baseline to 137 +/- 21 mm Hg during EECP; +93%; P < 0.0001) and mean intracoronary pressures (88 +/- 9 to 102 +/- 16 mm Hg; +16%; P = 0.006) with a decrease in systolic pressure (116 +/- 20 to 99 +/- 26 turn Hg; -15%; P = 0.002). The intracoronary Doppler measure of average peak velocity increased from 11 +/- 5 cm/s at baseline to 23 +/- 5 cm/s during EECP (+109%; P = 0.001). The TIMI frame count, a quantitative angiographic measure of coronary flow, showed a 28% increase in coronary flow during EECP compared with baseline (P = 0.001). Conclusions-EECP unequivocally and significantly increases diastolic and mean pressures and reduces systolic pressure in the central aorta and the coronary artery. Coronary artery flow, determined by both Doppler and angiographic techniques, is increased during EECP. The combined effects of systolic unloading and increased coronary perfusion pressure provide evidence that EECP may serve as a potential mechanical assist device.
引用
收藏
页码:1237 / 1242
页数:6
相关论文
共 30 条
[1]
CLINICAL-ASSESSMENT OF EXTERNAL-PRESSURE CIRCULATORY ASSISTANCE IN ACUTE MYOCARDIAL-INFARCTION - REPORT OF A COOPERATIVE CLINICAL-TRIAL [J].
AMSTERDAM, EA ;
BANAS, J ;
CRILEY, JM ;
LOEB, HS ;
MUELLER, H ;
WILLERSON, JT ;
MASON, DT .
AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (02) :349-356
[2]
AMSTERDAM EA, 1977, ADV CARDIOL, V23, P142
[3]
The multicenter study of enhanced external counterpulsation (MUST-EECP): Effect of EECP on exercise-induced myocardial ischemia and anginal episodes [J].
Arora, RR ;
Chou, TM ;
Jain, D ;
Fleishman, B ;
Crawford, L ;
McKiernan, T ;
Nesto, RW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (07) :1833-1840
[4]
Arora RR, 2001, J INVEST MED, V49, P500
[5]
SEQUENCED EXTERNAL COUNTERPULSATION AND INTRA-AORTIC BALLOON PUMPING IN CARDIOGENIC-SHOCK [J].
COHEN, LS ;
MULLINS, CB ;
MITCHELL, JH .
AMERICAN JOURNAL OF CARDIOLOGY, 1973, 32 (05) :656-661
[6]
Dib N, 1998, CATHETER CARDIO DIAG, V45, P382, DOI 10.1002/(SICI)1097-0304(199812)45:4<382::AID-CCD6>3.0.CO
[7]
2-4
[8]
TIMI frame count: A quantitative method of assessing coronary artery flow [J].
Gibson, CM ;
Cannon, CP ;
Daley, WL ;
Dodge, JT ;
Alexander, B ;
Marble, SJ ;
McCabe, CH ;
Raymond, L ;
Fortin, T ;
Poole, WK ;
Braunwald, E .
CIRCULATION, 1996, 93 (05) :879-888
[9]
GIRON F, 1966, SURGERY, V60, P894
[10]
EFFECTS OF PULSED EXTERNAL AUGMENTATION OF DIASTOLIC PRESSURE ON CORONARY AND SYSTEMIC HEMODYNAMICS IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
KERN, MJ ;
HENRY, RH ;
LEMBO, N ;
PARK, RC ;
LUJAN, MS ;
FERRY, D ;
OROURKE, RA .
AMERICAN HEART JOURNAL, 1985, 110 (04) :727-735