Real-time interactive MRI on a conventional scanner

被引:171
作者
Kerr, AB
Pauly, JM
Hu, BS
Li, KC
Hardy, CJ
Meyer, CH
Macovski, A
Nishimura, DG
机构
[1] STANFORD UNIV,DIV CARDIOVASC MED,STANFORD,CA 94305
[2] STANFORD UNIV,DEPT RADIOL,STANFORD,CA 94305
[3] GE CO,CORP RES & DEV,SCHENECTADY,NY 12301
关键词
MRI; real-time; interactive; fluoroscopy;
D O I
10.1002/mrm.1910380303
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
A real-time interactive MRI system capable of localizing coronary arteries and imaging arrhythmic hearts in real-time is described. Non-2DFT acquisition strategies such as spiral-interleaf, spiral-ring, and circular echo-planar imaging provide short scan times on a conventional scanner. Real-time gridding reconstruction at 8-20 images/s is achieved by distributing the reconstruction on general-purpose UNIX workstations. An X-windows application provides interactive control. A six-interleaf spiral sequence is used for cardiac imaging and can acquire six images/s. A sliding window reconstruction achieves display rates of 16-20 images/s. This allows cardiac images to be acquired in real-time, with minimal motion and flow artifacts, and without breath holding or cardiac gating. Abdominal images are acquired at over 2.5 images/s with spiral-ring or circular echo-planar sequences. Reconstruction rates are 8-10 images/s. Rapid localization in the abdomen is demonstrated with the spiral-ring acquisition, whereas peristaltic motion in the small bowel is well visualized using the circular echo-planar sequence.
引用
收藏
页码:355 / 367
页数:13
相关论文
共 55 条
[1]
BROWN C, 1994, DISTRIBUTED PROGRAMM
[2]
FOCUSED US SYSTEM FOR MR IMAGING-GUIDED TUMOR ABLATION [J].
CLINE, HE ;
HYNYNEN, K ;
WATKINS, RD ;
ADAMS, WJ ;
SCHENCK, JF ;
ETTINGER, RH ;
FREUND, WR ;
VETRO, JP ;
JOLESZ, FA .
RADIOLOGY, 1995, 194 (03) :731-737
[3]
MR TEMPERATURE MAPPING OF FOCUSED ULTRASOUND SURGERY [J].
CLINE, HE ;
HYNYNEN, K ;
HARDY, CJ ;
WATKINS, RD ;
SCHENCK, JF ;
JOLESZ, FA .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) :628-636
[4]
DEBBINS J, 1995, P SMR 3 ANN M NIC, P342
[5]
DUNN JT, 1984, ARCH SURG-CHICAGO, V119, P1305
[6]
Geist A, 1994, PVM PARALLEL VIRTUAL
[7]
Glenn W. E., 1988, Proceedings of the SPIE - The International Society for Optical Engineering, V901, P258, DOI 10.1117/12.944729
[8]
A real-time reconstruction system for magnetic resonance imaging [J].
Gmitro, AF ;
Ehsani, AR ;
Berchem, TA ;
Snell, RJ .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) :734-740
[9]
SNAPSHOT FLASH MRI - APPLICATIONS TO T1, T2, AND CHEMICAL-SHIFT IMAGING [J].
HAASE, A .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) :77-89
[10]
FLASH IMAGING - RAPID NMR IMAGING USING LOW FLIP-ANGLE PULSES [J].
HAASE, A ;
FRAHM, J ;
MATTHAEI, D ;
HANICKE, W ;
MERBOLDT, KD .
JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (02) :258-266