Simultaneous determination of Cd and Pb in foodstuffs by electrothermal atomic absorption spectrometry

被引:73
作者
Correia, PRM [1 ]
Oliveira, E [1 ]
Oliveira, PV [1 ]
机构
[1] Univ Sao Paulo, Inst Quim, BR-05508900 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
simultaneous determination; atomic absorption spectrometry; foodstuffs; cadmium; lead;
D O I
10.1016/S0003-2670(99)00761-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the simultaneous determination of cadmium and lead in foodstuffs by electrothermal atomic absorption spectrometry (ETAAS) with a transversely heated graphite atomizer (THGA) and Zeeman-effect background corrector is proposed. The samples (0.500 g) were digested to clear solutions with 5.0 mi concentrated nitric acid in a closed vessel microwave oven. Among various chemical modifiers tested, the best recovery and repeatability results were obtained with a 0.5% (w/v) NH4H2PO4 + 0.03% (w/v) Mg(NO3)(2) mixture. The pyrolysis and atomization temperatures for the simultaneous determination of cadmium and lead were 750 and 1600 degrees C, respectively. Tests carried out with several individual concomitants were performed and did not reveal significant interference on cadmium and lead atomization. Characteristic masses were 1.46 pg for cadmium (RSD = 4.0%) with 8.0% for reproducibility and 36.7 pg for lead (RSD = 2.6%) with 2.0% for reproducibility. The detection limits obtained were 0.38 pg (n = 20, 3 delta) for cadmium and 9.3 pg (n = 20, 3 delta) for lead. The relative standard deviations based on five measurements for each of the reference solutions (0.25-4.0 mu g Cd2+ l(-1)) and (2.5-40 mu g Pb2+ l(-1)) were always lower than 6.0%. The reliability of the entire procedure was confirmed by spike-tests or analysis of certified reference material (CRM) as spinach (No. 1570a) and bovine liver(No. 1577b) from NIST. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:205 / 211
页数:7
相关论文
共 23 条
[1]  
DAHER RT, 1995, ANAL CHEM, V67, pR405
[2]   DETERMINATION OF CADMIUM AND LEAD IN BLOOD REFERENCE SAMPLES BY SIMULTANEOUS GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
DEVAL, A ;
SNEDDON, J .
MICROCHEMICAL JOURNAL, 1995, 52 (01) :96-100
[3]   DIRECT DETERMINATION OF CADMIUM AND LEAD IN GEOLOGICAL AND PLANT MATERIALS BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
DOLINSEK, F ;
STUPAR, J ;
VRSCAJ, V .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (08) :653-660
[4]   DEVELOPMENTS AND APPLICATIONS OF MULTIELEMENT GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
FARAH, KS ;
SNEDDON, J .
APPLIED SPECTROSCOPY REVIEWS, 1995, 30 (04) :351-371
[5]  
*FCC IV, 1996, GEN TEST ASS, P763
[6]  
Goyer R.A., 1995, Metal toxicology
[7]  
Harnly JM, 1996, FRESEN J ANAL CHEM, V355, P501
[8]   EFFECT OF FURNACE ATOMIZATION TEMPERATURES ON SIMULTANEOUS MULTIELEMENT ATOMIC-ABSORPTION MEASUREMENT USING A TRANSVERSELY-HEATED GRAPHITE ATOMIZER [J].
HARNLY, JM ;
RADZIUK, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (03) :197-206
[9]   Performances and practical applications of simultaneous multi-element electrothermal atomic absorption spectrometry the case of the SIMAA 6000 [J].
Hoenig, M ;
Cilissen, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (9-10) :1443-1449
[10]   Comparison of chemical modifiers for the determination of lead in water samples with electrothermal atomic absorption spectrometry [J].
Liang, YZ ;
Xu, YP .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (08) :855-858