Validation of a newly developed B-mode image-processing technique versus wall-tracking ultrasound for the study of wall mechanics in small-calibre arteries

被引:5
作者
Vernhet, H
Demaria, R
Juan, JM
Oliva-Lauraire, MC
Quéré, I
Gariépy, J
Sénac, JP
Dauzat, M
机构
[1] Univ Montpellier I, Lab Cardiovasc Physiol, Fac Med, F-30907 Nimes, France
[2] Montpellier Univ Hosp, Dept Thorac & Cardiovasc Imaging, Montpellier, France
[3] Hop Broussais, Dept Cardiovasc Prevent Med, Paris, France
关键词
artery; B-mode ultrasound; compliance; echo-tracking; experimental study; rabbit; stent;
D O I
10.1046/j.1475-097X.2002.00415.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Purpose: To validate a newly developed image-processing technique for the assessment of arterial wall compliance and distensibility from non-invasive B-mode ultrasound compared with the invasive wall-tracking technique. Materials and methods: Arterial wall compliance and distensibility coefficient were measured invasively by wall-tracking with an ultrasonic transducer implanted on the vessel wall, and non-invasively by automatic processing of B-mode ultrasound images, with a dedicated workstation and software (I (O) over cap 3.1, I (O) over cap DP, Paris). Measurements were performed in the normal aorta of five animals, and upstream, at the stent level, and downstream from the stent in eight other animals (immediately after stenting in six, and 3 months later in four), for a total of 3 5 paired measurements. Results: There was no significant difference between the two techniques for compliance but there was a significant difference in diameter (P<0.005) and distensibility (P<0.05) as external ultrasound measured the inner diameter, while wall-tracking measured the outer diameter. Agreement between the two methods as assessed by the Bland-Altman approach was acceptable for aortic diameter, compliance and distensibility. Conclusion: Automatic processing of B-mode ultrasound images is a reliable non-invasive technique to assess the compliance of small-calibre arteries.
引用
收藏
页码:180 / 186
页数:7
相关论文
共 40 条
[1]   DIAMETER AND ELASTICITY OF ASCENDING AORTA DURING INFUSION OF NORADRENALINE [J].
AARS, H .
ACTA PHYSIOLOGICA SCANDINAVICA, 1971, 83 (01) :133-&
[2]   ARTERIAL-WALL MECHANICS IN CONSCIOUS DOGS - ASSESSMENT OF VISCOUS, INERTIAL, AND ELASTIC-MODULI TO CHARACTERIZE AORTIC-WALL BEHAVIOR [J].
ARMENTANO, RL ;
BARRA, JG ;
LEVENSON, J ;
SIMON, A ;
PICHEL, RH .
CIRCULATION RESEARCH, 1995, 76 (03) :468-478
[3]   CHANGES IN ARTERIAL-WALL COMPLIANCE AFTER ENDOVASCULAR STENTING [J].
BACK, M ;
KOPCHOK, G ;
MUELLER, M ;
CAVAYE, D ;
DONAYRE, C ;
WHITE, RA .
JOURNAL OF VASCULAR SURGERY, 1994, 19 (05) :905-911
[4]   ASSESSMENT OF SMOOTH-MUSCLE CONTRIBUTION TO DESCENDING THORACIC AORTIC ELASTIC MECHANICS IN CONSCIOUS DOGS [J].
BARRA, JG ;
ARMENTANO, RL ;
LEVENSON, J ;
FISCHER, EIC ;
PICHEL, RH ;
SIMON, A .
CIRCULATION RESEARCH, 1993, 73 (06) :1040-1050
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Arterial wall compliance after diode laser assisted microanastomosis:: A comparative study with conventional manual microanastomosis on the rabbit femoral artery [J].
Demaria, RG ;
Lhôte, FM ;
Dauzat, MM ;
Oliva-Lauraire, MC ;
Juan, JM ;
Vernhet, H ;
Aymard, T ;
Chaptal, PA ;
Godlewski, G .
LASERS IN MEDICAL SCIENCE, 2000, 15 (03) :207-213
[7]   ESTIMATION OF ARTERIAL STIFFNESS, COMPLIANCE, AND DISTENSIBILITY FROM M-MODE ULTRASOUND MEASUREMENTS OF THE COMMON CAROTID-ARTERY [J].
GAMBLE, G ;
ZORN, J ;
SANDERS, G ;
MACMAHON, S ;
SHARPE, N .
STROKE, 1994, 25 (01) :11-16
[8]   REGIONAL VOLUME DISTENSIBILITY OF CANINE THORACIC AORTA DURING MODERATE TREADMILL EXERCISE [J].
GENTILE, BJ ;
CHUONG, CJC ;
ORDWAY, GA .
CIRCULATION RESEARCH, 1988, 63 (06) :1012-1019
[9]   Experimental and clinical validation of arterial diameter waveform and intimal media thickness obtained from B-mode ultrasound image processing [J].
Graf, S ;
Gariepy, J ;
Massonneau, M ;
Armentano, RL ;
Mansour, S ;
Barra, JG ;
Simon, A ;
Levenson, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (09) :1353-1363
[10]   SPATIAL AND TEMPORAL CHANGES IN COMPLIANCE FOLLOWING IMPLANTATION OF BIORESORBABLE VASCULAR GRAFTS [J].
GREISLER, HP ;
JOYCE, KA ;
KIM, DU ;
PHAM, SM ;
BERCELI, SA ;
BOROVETZ, HS .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (11) :1449-1461