System dynamic model and temperature control of a thermoelectric cooler

被引:82
作者
Huang, BJ [1 ]
Duang, CL [1 ]
机构
[1] Natl Taiwan Univ, Dept Mech Engn, Taipei, Taiwan
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2000年 / 23卷 / 03期
关键词
refrigerating system; thermoelectricity; operating; simulation; measurement; accuracy;
D O I
10.1016/S0140-7007(99)00045-6
中图分类号
O414.1 [热力学];
学科分类号
摘要
A linear dynamic model of the thermoelectric cooler including the heat sink and the cooling-load heat exchanger was derived using small-signal linearization method. It shows that the dynamic model of a thermoelectric cooler has two poles and one zero. The linear dynamic model is shown to vary with operating conditions. A linear feedback system is designed for the cold-end temperature control of a thermoelectric cooler using the average linear dynamic model of the thermoelectric cooler and a PDF controller structure. The step response tests show that the controller has a very satisfactory performance. Some tests under variable cooling load and ambient temperature are also performed to examine the disturbance-rejection property of the controller. Experimental results show that the cold-end temperature can be maintained at the fixed value within +/-0.1 degrees C irrespective of the variations of the cooling load and the ambient conditions. (C) 2000 Elsevier Science Ltd and IIR. All rights reserved.
引用
收藏
页码:197 / 207
页数:11
相关论文
共 10 条
  • [1] Andersen JR, 1962, ADV ENERG CONVERS, V2, P241, DOI DOI 10.1016/0365-1789(62)90028-0
  • [2] TRANSIENT BEHAVIOR OF CASCADE THERMOELECTRIC HEAT PUMPS
    BYWATERS, RP
    BLUM, HA
    [J]. ENERGY CONVERSION, 1970, 10 (04): : 193 - &
  • [3] GOLDSMID HJ, 1986, ELECT REFRIGERATION, pCH8
  • [4] GRAY P, 1960, DYNAMIC BEHAV THERMO
  • [5] NUMERICAL-ANALYSIS OF TRANSIENT-BEHAVIOR OF THERMOELECTRIC COOLERS
    HOYOS, GE
    RAO, KR
    JERGER, D
    [J]. ENERGY CONVERSION, 1977, 17 (01): : 23 - 29
  • [6] LEU MC, 1989, ASME, P452
  • [7] MARLOW R, 1982, 4 INT C THERM EN CON, P125
  • [8] PHELAN RM, FEEDBACK CONTROL SYS
  • [9] SOO SL, 1968, DIRECT ENERGY CONVER, pCH5
  • [10] STOECKER WF, 1963, ASHRAE, V5, P61