Comparison of B-mode and conventional Colour/Power Doppler ultrasound, contrast-enhanced Doppler ultrasound and spiral CT in the diagnosis of focal lesions of the liver: Results of a multicentre study

被引:21
作者
Beissert, M
Delorme, S
Mutze, S
Lees, WR
Bahner, ML
Filimonow, S
Gillams, AR
Zuna, I
Bauer, A
Jenett, M
机构
[1] Univ Wurzburg, Inst Rontgendiagnost, Dept Radiol, D-97080 Wurzburg, Germany
[2] German Canc Res Ctr, Dept Oncol Diagnost & Therapy, D-6900 Heidelberg, Germany
[3] Humboldt Univ, Charite Hosp, Dept Radiol, Berlin, Germany
[4] UCL, Hosp Trust, Dept Imaging Middlesex Hosp, London, England
[5] German Canc Res Ctr, Dept Radiooncol, D-6900 Heidelberg, Germany
[6] Schering AG, Clin Dev Ultrasound Contrast Media, D-1000 Berlin, Germany
来源
ULTRASCHALL IN DER MEDIZIN | 2002年 / 23卷 / 04期
关键词
ultrasound (US); liver neoplasms; Doppler studies; US contrast media;
D O I
10.1055/s-2002-34051
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aim: In patients with lesions of the liver we compared diagnoses based on different methods of ultrasound as well as spiral CT with the final diagnosis reached at the time of the patient's discharge from hospital. Method: From records of a prospective multicentre study including 90 liver lesions investigated with B-mode baseline and conventional colour/power Doppler ultrasound, contrast-enhanced colour/power Doppler ultrasound and spiral-CT, we evaluated only those where diagnoses for all modalities were available, and where the diagnosis at discharge comprising all clinical, laboratory and imaging data as well as histologic proof was at least "highly probable". Results: 60 lesions met the inclusion criteria. 20 lesions were ultimately diagnosed as benign, and 40 as malignant. With respect to the diagnosis of malignancy, sensitivity was 92.5% (37/40) with B-mode and unenhanced conventional colour/power Doppler US ultrasound, 97.5% (39/40) with contrast-enhanced colour/ power Doppler ultrasound, and 100% with CT; the corresponding specificities were 65%(13/20), 85% (17/20) and 80% (16/20). 4 of 7 false positive, and 2 of 3 false negative results in the unenhanced technique were diagnosed correctly with contrast-enhanced Doppler ultrasound. Conclusion: Compared to conventional ultrasound, contrast-enhanced Doppler ultrasound improved the diagnostic accuracy in 10% of the cases. Its accuracy in our study was equal to that of CT.
引用
收藏
页码:245 / 250
页数:6
相关论文
共 26 条
[1]  
Angeli E, 1994, Radiol Med, V87, P24
[2]   IMAGING OF TUMOR VASCULARIZATION OF HEPATOCELLULAR CARCINOMAS VIA ULTRASOUND ANGIOGRAPHY [J].
BECKER, D ;
GUNTER, E ;
HAHN, EG ;
HEYDER, N .
ULTRASCHALL IN DER MEDIZIN, 1995, 16 (03) :109-112
[3]  
Campani R, 1994, Radiol Med, V87, P32
[4]  
Ernst H, 1996, J CLIN ULTRASOUND, V24, P31, DOI 10.1002/(SICI)1097-0096(199601)24:1<31::AID-JCU5>3.0.CO
[5]  
2-M
[6]  
FUJIMOTO M, 1994, AJR, V163, P247
[7]   Ultrasound of focal liver lesions [J].
Harvey, CJ ;
Albrecht, T .
EUROPEAN RADIOLOGY, 2001, 11 (09) :1578-1593
[8]   DIFFERENTIAL-DIAGNOSIS OF HEPATIC-TUMORS (HEPATOMA, HEMANGIOMA, AND METASTASIS) WITH CT - VALUE OF 2-PHASE INCREMENTAL IMAGING [J].
HONDA, H ;
MATSUURA, Y ;
ONITSUKA, H ;
MURAKAMI, J ;
KANEKO, K ;
MURAYAMA, S ;
KANEMATSU, T ;
MASUDA, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (04) :735-740
[9]   Vascularisation patterns in focal liver lesions: Comparison of plain and signal-enhanced amplitude-modulated colour duplex sonography. [J].
Hosten, N ;
Steger, W ;
Bechstein, WO ;
Zendel, WJ ;
Venz, S ;
Lemke, AJ ;
Weber, S ;
Vogl, TJ ;
Felix, R .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 166 (06) :507-513
[10]  
KAMALOV E, 1998, EUR J ULTRASOUND, V7, P101