Predicting eventual success or failure to wean in patients receiving long-term mechanical ventilation

被引:34
作者
Gluck, EH
Corigan, L
机构
[1] VET ADM MED CTR,N CHICAGO,IL 60064
[2] VENCOR HOSP,NORTHLAKE,IL
[3] RUSH PRESBYTERIAN ST LUKES MED CTR,CHICAGO,IL 60612
关键词
long-term mechanical ventilation; protocols; weaning;
D O I
10.1378/chest.110.4.1018
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: To determine if the ultimate ability of a long-term ventilated patient to wean can be predicted at the time of his or her admission to a long-term ventilator unit. Design: Two-phased prospective study. Setting: Long-term ventilator facility university-affiliated. Subjects: Adults ventilated for an average of 3 weeks, who did not have sepsis and who did not have chest tubes of progressive neurologic impairment. Interventions: On admission to the long-term ventilator unit, historic factors, ventilator history, and the following laboratory and metabolic tests were obtained: electrolytes, serum calcium, magnesium, and phosphorus, WBC, hemoglobin, albumin, total protein, transferrin, oxygen consumption, carbon dioxide production, respiratory; quotient, and dead space/tidal volume. The patients were then placed in a weaning protocol utilizing increasing duration of pressure support ventilation during the day with complete rest at night. Forty-two days after enrollment in the study, representing three times the duration of the weaning protocol, the patients who successfully weaned were compared to those who remained ventilator dependent (n=20). Patients who died or were transferred to another institution were excluded from this phase of the study, because we were trying to develop parameters that would be predictive of successful weaning. A parameter was considered to be predictive, and retained for the scoring system, if it. produced at most 15% false-positives and false-negatives. A score of 0 was then assigned to the threshold value that produced no false-positive scoring system was then applied to a new prospective group of patients (n=72). Measurements and main results: Of all the parameters evaluated, only the following satisfied the false-positive and false-negative requirements; static compliance, airway resistance, dead space to tidal volume ratio, PaCO2, and frequency/tidal volume. Applying these, in the scoring system, to the initial group of patients, demonstrated that a score greater than 3 was associated with failure to wean; a score less than 3 was associated with successful weaning, and a score of 3 was not predictive. Using these thresholds, the data were applied to the new prospective group of patients, which again demonstrated that a score of greater than 3 was associated with failure to wean in all cases. A score less than 3 was again associated with successful weaning but there mere two false-positives. The sensitivity, specificity, and positive predictive and negative predictive values for the scoring system were 1.0, 0.91, 0.83, and 1.0, respectively. None of the individual parameters included in the scoring system demonstrated equivalent statistical results, All but two of the patients who died prior to finishing a the weaning period had weaning scores, which suggested that they would not be successfully weaned. Conclusions: Parameters that are generally available, when combined into a scoring system, can predict at the time of admission to a long-term ventilator unit, in most cases, whether a patient will eventually wean. The scoring system resulted in no false-negatives and an acceptable number of false-positives. None of the individual parameters were as reliable as die scoring system as a whole.
引用
收藏
页码:1018 / 1024
页数:7
相关论文
共 13 条
[1]   COMPARISON OF 3 METHODS OF GRADUAL WITHDRAWAL FROM VENTILATORY SUPPORT DURING WEANING FROM MECHANICAL VENTILATION [J].
BROCHARD, L ;
RAUSS, A ;
BENITO, S ;
CONTI, G ;
MANCEBO, J ;
REKIK, N ;
GASPARETTO, A ;
LEMAIRE, F .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 150 (04) :896-903
[2]   A COMPARISON OF 4 METHODS OF WEANING PATIENTS FROM MECHANICAL VENTILATION [J].
ESTEBAN, A ;
FRUTOS, F ;
TOBIN, MJ ;
ALIA, I ;
SOLSONA, JF ;
VALVERDU, I ;
FERNANDEZ, R ;
DELACAL, MA ;
BENITO, S ;
TOMAS, R ;
CARRIEDO, D ;
MACIAS, S ;
BLANCO, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 332 (06) :345-350
[3]   COMPARISON OF STANDARD WEANING PARAMETERS AND THE MECHANICAL WORK OF BREATHING IN MECHANICALLY VENTILATED PATIENTS [J].
FIASTRO, JF ;
HABIB, MP ;
SHON, BY ;
CAMPBELL, SC .
CHEST, 1988, 94 (02) :232-238
[4]  
FISHMAN A, 1992, PULMONARY DIS DISORD, P2383
[5]   OUTCOME OF PATIENTS CARED FOR IN A VENTILATOR-DEPENDENT UNIT IN A GENERAL-HOSPITAL [J].
GRACEY, DR ;
NAESSENS, JM ;
VIGGIANO, RW ;
KOENIG, GE ;
SILVERSTEIN, MD ;
HUBMAYR, RD .
CHEST, 1995, 107 (02) :494-499
[6]   OXYGEN-UPTAKE DURING WEANING FROM MECHANICAL VENTILATION [J].
HUBMAYR, RD ;
LOOSBROCK, LM ;
GILLESPIE, DJ ;
RODARTE, JR .
CHEST, 1988, 94 (06) :1148-1155
[7]   APACHE-II - A SEVERITY OF DISEASE CLASSIFICATION-SYSTEM [J].
KNAUS, WA ;
DRAPER, EA ;
WAGNER, DP ;
ZIMMERMAN, JE .
CRITICAL CARE MEDICINE, 1985, 13 (10) :818-829
[8]  
MATTSON DE, 1986, STAT DIFFICULT CONCE, P68
[9]   CRITERIA FOR WEANING FROM PROLONGED MECHANICAL VENTILATION [J].
MORGANROTH, ML ;
MORGANROTH, JL ;
NETT, LM ;
PETTY, TL .
ARCHIVES OF INTERNAL MEDICINE, 1984, 144 (05) :1012-1016
[10]  
PARRILLO J, 1991, CURRENT THERAPY CRIT, P204