Use of the BACTEC mycobacteria growth indicator tube 960 automated system for recovery of mycobacteria from 9,558 extrapulmonary specimens, including urine samples

被引:52
作者
Hillemann, Doris [1 ]
Richter, Elvira [1 ]
Ruesch-Gerdes, Sabine [1 ]
机构
[1] Forschungszentrum, Nat Reference Ctr Mycobacteria, D-23845 Borstel, Germany
关键词
D O I
10.1128/JCM.00829-06
中图分类号
Q93 [微生物学];
学科分类号
071005 [微生物学]; 100705 [微生物与生化药学];
摘要
The BACTEC Mycobacteria Growth Indicator Tube 960 (MGIT 960) system was applied for recovery of mycobacteria from extrapulmonary specimens and compared with solid media (Lowenstein-Jensen and Stone-brink). A total of 9,558 specimens were investigated, comprising 3,074 body fluids, 1,878 tissues, and 2,069 urine samples, from which the recovery of mycobacteria was not yet established for MGIT 960. In total, the MGIT 960 was able to detect 446 (90.3%) of the 494 isolates of Mycobacterium tuberculosis complex (MTBC) and 223 (86.0%) out of the 259 isolates of nontuberculous mycobacteria (NTM). In comparison to this, culture on solid medium revealed 358 (72.6%) MTBC isolates and 164 (66.8%) NTM isolates. While 136 (27.6%) of the MTBC isolates and 95 (19.2%) of the NTM isolates were recovered from the MGIT 960 only, 48 (9.7%) of the MTBC isolates and 36 (13.9%) NTM isolates grew only on solid media. Thus, the overall sensitivities for the recovery of mycobacteria from extrapulmonary specimens with MGIT 960 and solid media were 88.8% and 69.3%, respectively. However, the efficiency of the MGIT 960 system can be maximized with additional culture on solid media.
引用
收藏
页码:4014 / 4017
页数:4
相关论文
共 19 条
[1]
Alcaide F, 2000, J CLIN MICROBIOL, V38, P398
[2]
Alsenberg GM, 2005, CANCER, V104, P2882
[3]
Comparison of mycobacteria growth indicator tube with BACTEC 460 for detection and recovery of mycobacteria from clinical specimens [J].
Badak, FZ ;
Kiska, DL ;
Setterquist, S ;
Hartley, C ;
OConnell, MA ;
Hopfer, RL .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (09) :2236-2239
[4]
Molecular diagnostics in tuberculosis [J].
Cheng, VCC ;
Yew, WW ;
Yuen, KY .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2005, 24 (11) :711-720
[5]
Meta-analysis of BACTEC MGIT 960 and BACTEC 460 TB, with or without solid media, for detection of mycobacteria [J].
Cruciani, M ;
Scarparo, C ;
Malena, M ;
Bosco, O ;
Serpelloni, G ;
Mengoli, C .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (05) :2321-2325
[6]
Multicenter evaluation of the BACTEC MGIT 960 system for recovery of mycobacteria [J].
Hanna, BA ;
Ebrahimzadeh, A ;
Elliott, LB ;
Morgan, MA ;
Novak, SM ;
Rusch-Gerdes, S ;
Acio, M ;
Dunbar, DF ;
Holmes, TM ;
Rexer, CH ;
Savthyakumar, C ;
Vannier, AM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (03) :748-752
[7]
Comparison of the automated nonradiometric Bactec MGIT 960 system with Lowenstein-Jensen, Coletsos, and Middlebrook 7H11 solid media for recovery of mycobacteria [J].
Idigoras, P ;
Beristain, X ;
Iturzaeta, A ;
Vicente, D ;
Pérez-Trallero, E .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2000, 19 (05) :350-354
[8]
Evaluation of the BACTEC™ MGIT™ 960 system for the recovery of mycobacteria [J].
Kanchana, MV ;
Cheke, D ;
Natyshak, I ;
Connor, B ;
Warner, A ;
Martin, T .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2000, 37 (01) :31-36
[9]
Lee JJ, 2003, INT J TUBERC LUNG D, V7, P569
[10]
Lu DS, 2002, AM J CLIN PATHOL, V118, P542, DOI 10.1309/65KN-2M7E-7MNN-X0TA