Day to day variability of the dark-adapted pupil diameter

被引:37
作者
Brown, SA
Khanani, AM
Xu, KT
机构
[1] Texas Tech Univ, Ctr Hlth Sci, Dept Ophthalmol & Visual Sci, Lubbock, TX 79409 USA
[2] Texas Tech Univ, Ctr Hlth Sci, Dept Hlth Serv Res & Management, Lubbock, TX 79409 USA
关键词
D O I
10.1016/j.jcrs.2003.09.060
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the individual variability of the dark-adapted pupil diameter over 2 testing sessions using a standardized dark-adaptation protocol. Setting. Texas Tech University Health Sciences Center, Lubbock, Texas, USA. Methods: In this prospective observational cohort study, 40 volunteers with no history of ocular disease, surgery, or injury other than requirement for refractive correction were included. The right eye was tested. A standardized dark-adaptation protocol was used that controlled for accommodation and patient alertness. Infrared, still digital photographs were taken after 5 and 10 minutes of dark adaptation and analyzed independently by 2 investigators using digital-image software. Two test sessions were performed 1 to 7 days apart. Lifestyle factors such as sleep, diet, and exercise were not controlled. Results: The mean subject age was 31.5 years (range 20 to 49 years). There were 20 men; 27 subjects wore correction for myopia, and 13 wore no correction. The mean interval between test sessions was 2 days (range 1 to 7 days). The mean difference and 95% confidence intervals for pupil diameter difference between sessions were as follows: 5-minute readings, +0.032 mm (-0.030 to +0.094); 10-minute readings, -0.006 mm (-0.059 to +0.047); mean of 5- and 10-minute readings, +0.013 mm (-0.038 to +0.064). Using the paired t test, the pupil diameter did not differ significantly between sessions in 5-minute dark adaptation (P = .2980), 10-minute dark adaptation (P = .8263), or the mean (P = .6049). Conclusion: Using a consistent dark-adaptation protocol that controlled for alertness, individuals aged 20 to 49 years showed no significant variation in dark-adapted pupil diameter when tested twice in 1 week.
引用
收藏
页码:639 / 644
页数:6
相关论文
共 17 条
[1]   Preoperative measurement of scotopic pupil dilation using an office pupillometer [J].
Colvard, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (12) :1594-1597
[2]  
DAVSON H, 1962, THE EYE, V2, pCH5
[3]  
ETTINGER ER, 1991, INVEST OPHTH VIS SCI, V32, P501
[4]   DIMENSIONS OF APPARENT PUPIL WHEN VIEWED AT OBLIQUE ANGLES [J].
HAINES, RF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1969, 68 (04) :649-&
[5]   Measurement of pupil size with the video screen of an infrared autorefractor [J].
Ing, E ;
Ing, T ;
Ing, S .
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2001, 36 (03) :145-146
[6]  
KOCH DD, 1991, OPHTHALMOLOGY, V98, P1030
[7]   THE PUPIL DARK RESPONSE IN NORMAL VOLUNTEERS [J].
KOLLARITS, CR ;
KOLLARITS, FJ ;
SCHUETTE, WH ;
WHITEHOUSE, WC ;
GUNKEL, RD .
CURRENT EYE RESEARCH, 1982, 2 (04) :255-259
[8]  
LOEWENFELD IE, 1974, AM J OPHTHALMOL, V78, P304, DOI 10.1016/0002-9394(74)90093-2
[9]  
LOEWENFELD IE, 1993, PUPIL ANAT PHYSL CLI
[10]   Comparison of the pupil card and pupillometer in measuring pupil size [J].
Pop, M ;
Payette, Y ;
Santoriello, E .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :283-288