Subcritical water chromatography with flame ionization detection

被引:133
作者
Miller, DJ
Hawthorne, SB
机构
[1] Ener. and Environ. Research Center, University of North Dakota, Grand Forks
关键词
D O I
10.1021/ac960729j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A chromatographic method has been developed that allows subcritical (hot/liquid) water to be used as a mobile phase for packed-column reverse-phase LC with solute detection by name ionization detection, Detection limits (S/N > 3:1 for butanol) of 1 ng were achieved with water flows of 20 and 50 mu L/min and 5 ng with flows ranging from 100 to 200 mu L/min. Quantitative determinations of ethanol in alcoholic beverages are in excellent agreement with label values and replicate injections have RSDs of similar to 2%. Increasing the column temperature lowers the dielectric constant (polarity) of water, decreases the elution time, and improves the peak shape for compounds ranging from alcohols to hydroxy-substituted benzenes to amino acids. Temperature programming up to 175 degrees C can be used to improve separations and decrease analysis times.
引用
收藏
页码:623 / 627
页数:5
相关论文
共 11 条
[1]   NEW THERMIONIC DETECTOR UTILIZING ORTHOGONAL NEBULIZATION FOR CAPILLARY COLUMN LIQUID-CHROMATOGRAPHY [J].
GLUCKMAN, JC ;
NOVOTNY, M .
JOURNAL OF CHROMATOGRAPHY, 1984, 314 (NOV) :103-110
[2]  
HAAR L, 1984, NBS NATIONAL RES COU
[3]   EXTRACTION OF ORGANIC POLLUTANTS FROM ENVIRONMENTAL SOLIDS WITH SUBCRITICAL AND SUPERCRITICAL WATER [J].
HAWTHORNE, SB ;
YANG, Y ;
MILLER, DJ .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2912-2920
[4]   FLAME-BASED THERMIONIC DETECTION COUPLED ONLINE WITH MICROCOLUMN LIQUID-CHROMATOGRAPHY .2. CHARACTERIZATION OF THE SYSTEM [J].
KIENTZ, CE ;
VERWEIJ, A ;
DEJONG, GJ ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1992, 626 (01) :71-80
[5]   FLAME-BASED THERMIONIC DETECTION COUPLED ONLINE WITH MICROCOLUMN LIQUID-CHROMATOGRAPHY .1. OPTIMIZATION OF THE SYSTEM [J].
KIENTZ, CE ;
VERWEIJ, A ;
DEJONG, GJ ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1992, 626 (01) :59-69
[6]   FLOW CHARACTERISTICS AND TECHNOLOGY OF CAPILLARY COLUMNS WITH INNER DIAMETERS LESS THAN 15 MU-M IN LIQUID-CHROMATOGRAPHY [J].
KREJCI, M ;
TESARIK, K ;
RUSEK, M ;
PAJUREK, J .
JOURNAL OF CHROMATOGRAPHY, 1981, 218 (1-3) :167-178
[7]   FLAME EMISSION DETECTION IN MICROCOLUMN LIQUID-CHROMATOGRAPHY [J].
MCGUFFIN, VL ;
NOVOTNY, M .
ANALYTICAL CHEMISTRY, 1981, 53 (07) :946-951
[8]   THERMIONIC DETECTION IN MICROCOLUMN LIQUID-CHROMATOGRAPHY [J].
MCGUFFIN, VL ;
NOVOTNY, M .
ANALYTICAL CHEMISTRY, 1983, 55 (14) :2296-2302
[9]   GAS-SOLID CHROMATOGRAPHY OF ORGANIC COMPOUNDS USING STEAM AS CARRIER GAS [J].
NONAKA, A .
ANALYTICAL CHEMISTRY, 1972, 44 (02) :271-&
[10]   GAS-CHROMATOGRAPHY WITH VAPORS OF LOW-BOILING SUBSTANCES AS MOBILE PHASES [J].
RUDENKO, BA ;
BAYDAROVTSEVA, MA ;
KUZOVKIN, VA ;
KUCHEROV, VF .
JOURNAL OF CHROMATOGRAPHY, 1975, 104 (02) :271-275