Torsional Fracture of the Humerus after Subpectoral Biceps Tenodesis with an Interference Screw: A Biomechanical Cadaveric Study

被引:33
作者
Beason, David P. [1 ]
Shah, Jay P. [2 ]
Duckett, James W. [1 ]
Jost, Patrick W. [1 ]
Fleisig, Glenn S. [1 ]
Cain, E. Lyle, Jr. [1 ]
机构
[1] Amer Sports Med Inst, Birmingham, AL USA
[2] Univ Alabama Birmingham, Div Orthopaed Surg, Birmingham, AL USA
关键词
Biceps tenodesis; Biomechanical; Torsion; Spiral fracture; Humerus; Interference screw; ANTERIOR CRUCIATE LIGAMENT; CORTICAL BUTTON FIXATION; SUTURE ANCHOR FIXATION; LONG HEAD; MECHANICAL-PROPERTIES; TENDON; BONE; RECONSTRUCTION; MANAGEMENT; INJURIES;
D O I
10.1016/j.clinbiomech.2015.07.009
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Background: Humeral fracture following subpectoral biceps tenodesis has been previously reported; however, there are no published biomechanical studies reporting the resulting torsional strength of the humerus. Our purpose was to determine if there is an increased risk of humerus fracture after subpectoral biceps tenodesis with an interference screw and to determine if screw size is also a factor. We hypothesized that limbs receiving the procedure would have reduced failure torque and rotation under external rotation compared to untreated controls and that the larger screw size would result in inferior mechanical properties compared to the smaller. Methods: Twenty matched pairs of embalmed cadaveric humeri were subjected to subpectoral biceps tenodesis using either a 6.25 or 8.0 mm interference screw, with the untreated contralateral limb serving as a control. Each humerus was mechanically tested in torsional external rotation to failure. Findings: Maximum torque and rotation to failure were reduced in the tenodesis group compared to controls; however, there was no difference between screw sizes. When both screw sizes were combined into a single group, paired t-tests also showed similar differences. Interpretation: Based on our experiment, there is an increased risk for humerus spiral fracture when subjected to torsional external rotation after subpectoral biceps tenodesis with an interference screw compared to an intact humerus; however, there is not a significant difference between a 6.25 mm and 8.0 mm screw. Surgeons may elect to use alternative fixation methods in patients at high risk (e.g., overhead throwing athletes, etc.) for torsional loads and fracture. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:915 / 920
页数:6
相关论文
共 38 条
[1]
Resorbable fillers reduce stress risers from empty screw holes [J].
Alford, J. Winslow ;
Bradley, Michael P. ;
Fadale, Paul D. ;
Crisco, Joseph J. ;
Moore, Douglas C. ;
Ehrlich, Michael G. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2007, 63 (03) :647-654
[2]
[Anonymous], 2011, ATHLETIC SPORT ISSUE
[3]
Biomechanical Evaluation of a Unicortical Button Versus Interference Screw for Subpectoral Biceps Tenodesis [J].
Arora, Amarpal S. ;
Singh, Anshu ;
Koonce, Ryan C. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2013, 29 (04) :638-644
[4]
Barber F Alan, 2008, Instr Course Lect, V57, P527
[5]
Biomechanical Comparison of Intramedullary Cortical Button Fixation and Interference Screw Technique for Subpectoral Biceps Tenodesis [J].
Buchholz, Arne ;
Martetschlaeger, Frank ;
Siebenlist, Sebastian ;
Sandmann, Gunther H. ;
Hapfelmeier, Alexander ;
Lenich, Andreas ;
Millett, Peter J. ;
Stoeckle, Ulrich ;
Elser, Florian .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2013, 29 (05) :845-853
[6]
EFFECT OF FORMALDEHYDE FIXATION ON SOME MECHANICAL-PROPERTIES OF BOVINE BONE [J].
CURREY, JD ;
BREAR, K ;
ZIOUPOS, P ;
REILLY, GC .
BIOMATERIALS, 1995, 16 (16) :1267-1271
[7]
A Humerus Fracture in a Baseball Pitcher After Biceps Tenodesis [J].
Dein, Eric J. ;
Huri, Gazi ;
Gordon, John C. ;
McFarland, Edward G. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2014, 42 (04) :877-879
[8]
Magnetic resonance imaging analysis of bioabsorbable interference screws used for fixation of bone-patellar tendon-bone autografts in endoscopic reconstruction of the anterior cruciate ligament [J].
Drogset, JO ;
Grontvedt, T ;
Myhr, G .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (07) :1164-1169
[9]
Anatomy, Function, Injuries, and Treatment of the Long Head of the Biceps Brachii Tendon [J].
Elser, Florian ;
Braun, Sepp ;
Dewing, Christopher B. ;
Giphart, J. Erik ;
Millett, Peter J. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2011, 27 (04) :581-592
[10]
Biomechanical Comparison of Baseball Pitching and Long-Toss: Implications for Training and Rehabilitation [J].
Fleisig, Glenn S. ;
Bolt, Becky ;
Fortenbaugh, Dave ;
Wilk, Kevin E. ;
Andrews, James R. .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2011, 41 (05) :296-303