Development of a digital image database for chest radiographs with and without a lung nodule: Receiver operating characteristic analysis of radiologists' detection of pulmonary nodules

被引:688
作者
Shiraishi, J
Katsuragawa, S
Ikezoe, J
Matsumoto, T
Kobayashi, T
Komatsu, K
Matsui, M
Fujita, H
Kodera, Y
Doi, K
机构
[1] Osaka City Univ Hosp, Dept Radiol, Abeno Ku, Osaka, Osaka 5458586, Japan
[2] Iwate Med Univ, Dept Radiol, Morioka, Iwate 0208505, Japan
[3] Ehime Univ, Dept Radiol, Shigenobu, Ehime 7910295, Japan
[4] Yamaguchi Univ, Dept Radiol, Ube, Yamaguchi 7558506, Japan
[5] Kanazawa Univ, Dept Radiol, Kanazawa, Ishikawa 9200942, Japan
[6] Toshiba Co Ltd, Med Engn Div, Minato Ku, Tokyo 1058001, Japan
[7] Konica, Med Inaging Div, Hino, Tokyo 1918511, Japan
[8] Gifu Univ, Fac Engn, Dept Informat Sci, Gifu 5011193, Japan
[9] Nagoya Univ, Sch Hlth Sci, Dept Radiol Technol, Higashi Ku, Nagoya, Aichi 4618673, Japan
[10] Univ Chicago, Dept Radiol, Kurt Rossmann Labs Radiol Image Res, Chicago, IL 60637 USA
关键词
D O I
10.2214/ajr.174.1.1740071
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. We developed a digital image database (www.macnet.or.jp/jsrt2/cdrom_nodules.html) of 247 chest radiographs with and without a lung nodule. The aim of this study was to investigate the characteristics of image databases for potential use in various digital image research projects. Radiologists' detection of solitary pulmonary nodules included in the database was evaluated using a receiver operating characteristic (ROC) analysis. MATERIALS AND METHODS. One hundred and fifty-four conventional chest radiographs with a lung nodule and 93 radiographs without a nodule were selected from 14 medical centers and were digitized by a laser digitizer with a 2048 x 2048 matrix size (0.175-mm pixels) and a 12-bit gray scale. Lung nodule images were classified into five groups according to the degrees of subtlety shown. The observations of 20 participating radiologists were subjected to ROC analysis for detecting solitary pulmonary nodules, Experimental results (areas under the curve, A(z)) obtained from observer studies were used for characterization of five groups of lung nodules with different degrees of subtlety. RESULTS. ROC analysis showed that the database included a wide range of various nodules yielding A(z) values from 0.574 to 0.991 for the five categories of cases for different degrees of subtlety. CONCLUSION. This database can be useful for many purposes, including research, education, quality assurance, and other demonstrations.
引用
收藏
页码:71 / 74
页数:4
相关论文
共 9 条
[1]   PROPOSED STANDARD FOR IMAGE CYTOMETRY DATA FILES [J].
DEAN, P ;
MASCIO, L ;
OW, D ;
SUDAR, D ;
MULLIKIN, J .
CYTOMETRY, 1990, 11 (05) :561-569
[2]   SPATIAL-RESOLUTION REQUIREMENTS FOR DIGITAL CHEST RADIOGRAPHS - AN ROC STUDY OF OBSERVER PERFORMANCE IN SELECTED CASES [J].
LAMS, PM ;
COCKLIN, ML .
RADIOLOGY, 1986, 158 (01) :11-19
[3]   DIGITAL RADIOGRAPHY OF SUBTLE PULMONARY ABNORMALITIES - AN ROC STUDY OF THE EFFECT OF PIXEL SIZE ON OBSERVER PERFORMANCE [J].
MACMAHON, H ;
VYBORNY, CJ ;
METZ, CE ;
DOI, K ;
SABETI, V ;
SOLOMON, SL .
RADIOLOGY, 1986, 158 (01) :21-26
[4]  
Metz CE, 1998, STAT MED, V17, P1033, DOI 10.1002/(SICI)1097-0258(19980515)17:9<1033::AID-SIM784>3.0.CO
[5]  
2-Z
[6]  
NISHIKAWA RM, 1993, P SOC PHOTO-OPT INS, V1905, P548, DOI 10.1117/12.148620
[7]   EFFECT OF CASE SELECTION ON THE PERFORMANCE OF COMPUTER-AIDED DETECTION SCHEMES [J].
NISHIKAWA, RM ;
GIGER, ML ;
DOI, K ;
METZ, CE ;
YIN, FF ;
VYBORNY, CJ ;
SCHMIDT, RA .
MEDICAL PHYSICS, 1994, 21 (02) :265-269
[8]   THE USE OF CONTINUOUS AND DISCRETE CONFIDENCE JUDGMENTS IN RECEIVER OPERATING CHARACTERISTIC STUDIES OF DIAGNOSTIC-IMAGING TECHNIQUES [J].
ROCKETTE, HE ;
GUR, D ;
METZ, CE .
INVESTIGATIVE RADIOLOGY, 1992, 27 (02) :169-172
[9]  
SUCKLING J, 1994, INT CONGR SER, V1069, P375