Background. The CEREC system (Sirona Dental systems GmbH, Bensheim , Germany) is marking its 20th year of clinical service. The author reviews the literature on the effectiveness of this chairside CAD/CAM system. Types of Studies Reviewed. The author identified and reviewed clinical studies from 1985 through 2006 that included CEREC-generated inlays, onlays or crowns. These studies were conducted in both private practice and university settings. The author summarized the findings as they relate to postoperative sensitivity, restoration fracture, colour match, margin adaption and clinical longevity. Results. Although postoperative sensitivity was reported, it was due to mainly occlusal interferences. Long-term postoperative sensitivity was not a reported problem. Similar to other ceramic restorations, restoration fracture is the primary mode of failure for CEREC-generated restorations. Although margin wear is detected consistently, consequences of the wear leading to restoration failure were reported rarely. The survival probability of CEREC-generated restorations was reported to be approximately 97 percent for five years and 90 percent for 10 years. Clinical Implications. The low rate of restoration fracture and long-term clinical survivability document the deffectiveness of the CEREC system as a dependable, esthetic restorative option for patients.
引用
收藏
页码:22S / 31S
页数:10
相关论文
共 31 条
[1]
[Anonymous], [No title captured]
[2]
Berg NG, 1997, SWED DENT J, V21, P121
[3]
Bindl A, 2005, INT J PROSTHODONT, V18, P219
[4]
Survival rate of mono-ceramic and ceramic-core CAD/CAM-generated anterior crowns over 2-5 years [J].
Bindl, A ;
Mörmann, WH .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2004, 112 (02) :197-204
[5]
Clinical and SEM evaluation of all-ceramic chair-side CAD/CAM-generated partial crowns [J].
Bindl, A ;
Mörmann, WH .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2003, 111 (02) :163-169
[6]
Brauner AW, 1996, CAD/CIM IN AESTHETIC DENTISTRY, P217
[7]
Cerutti A, 1998, J DENT RES, V77, P913
[8]
Marginal fit and short-term clinical performance of porcelain-veneered CICERO, CEREC, and Procera onlays [J].
Denissen, H ;
Dozic, A ;
van der Zel, J ;
van Waas, M .
JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (05) :506-513
[9]
The clinical performance of CAD/CAM-generated composite inlays [J].
Fasbinder, DJ ;
Dennison, JB ;
Heys, DR ;
Lampe, K .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2005, 136 (12) :1714-1723
[10]
Fasbinder DJ, 1999, J DENT RES, V78, P444