Empirical procedure for the reduction of mixed-matrix effects in inductively coupled plasma atomic emission spectrometry using an internal standard and proportional correction

被引:36
作者
deBoer, JLM [1 ]
Velterop, M [1 ]
机构
[1] UNIV UTRECHT,DEPT GEOCHEM,NL-3508 TA UTRECHT,NETHERLANDS
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1996年 / 356卷 / 06期
关键词
D O I
10.1007/s0021663560362
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The matrix effects for single-matrix component (Na or Ca) and mixed-matrix component (Na plus Ca) systems were investigated for an inductively coupled plasma with radial viewing and employing ultrasonic nebulization. Correction for matrix effects was carried out using the internal standard ratio method and a method named 'proportional correction', both with scandium and yttrium as internal standard elements. The best correction was observed using proportional correction both for the single-matrix component systems and for the mixed-matrix component system.
引用
收藏
页码:362 / 370
页数:9
相关论文
共 33 条
[1]  
ALAMMAR A, 1994, ICP INFORMATION NEWS, V20, P335
[2]   STUDIES OF A RADIO-FREQUENCY INDUCTIVELY COUPLED ARGON PLASMA FOR OPTICAL EMISSION SPECTROMETRY .3. INTERFERENCE EFFECTS UNDER COMPROMISE CONDITIONS FOR SIMULTANEOUS MULTI-ELEMENT ANALYSIS [J].
BOUMANS, PWJM ;
DEBOER, FJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1976, 31 (06) :355-375
[3]   STUDIES OF AN INDUCTIVELY-COUPLED HIGH-FREQUENCY ARGON PLASMA FOR OPTICAL EMISSION SPECTROMETRY .2. COMPROMISE CONDITIONS FOR SIMULTANEOUS MULTIELEMENT ANALYSIS [J].
BOUMANS, PWJM ;
DEBOER, FJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1975, 30 (09) :309-334
[4]   EXPERIMENTAL-STUDY OF A 1-KW, 50-MHZ RF INDUCTIVELY COUPLED PLASMA WITH PNEUMATIC NEBULIZER, AND A DISCUSSION OF EXPERIMENTAL-EVIDENCE FOR A NONTHERMAL MECHANISM [J].
BOUMANS, PWJM ;
DEBOER, FJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1977, 32 (9-10) :365-395
[5]  
Boumans PWJM, 1987, INDUCTIVELY COUPLE 1
[6]   PERFORMANCE-CHARACTERISTICS OF AN ULTRASONIC NEBULIZER COUPLED TO A 40.68 MHZ INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETER [J].
BRENNER, IB ;
BREMIER, P ;
LEMARCHAND, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (06) :819-824
[7]   CONTINUOUS INTERNAL STANDARDIZATION WITH A SEQUENTIAL INDUCTIVELY COUPLED ARGON PLASMA SYSTEM [J].
CATTERICK, T .
ANALYST, 1984, 109 (11) :1465-1467
[8]   ULTRASONIC NEBULIZATION OF LIQUID SAMPLES FOR ANALYTICAL INDUCTIVELY COUPLED PLASMA-ATOMIC SPECTROSCOPY - AN UPDATE [J].
FASSEL, VA ;
BEAR, BR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1986, 41 (10) :1089-1113
[9]   INFLUENCE OF OPERATING-CONDITIONS ON THE EFFECTS OF ACIDS IN INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
FERNANDEZ, A ;
MURILLO, M ;
CARRION, N ;
MERMET, JM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (03) :217-221
[10]   EASILY IONIZABLE ELEMENT (EIE) INTERFERENCES IN INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY .2. MINIMIZATION OF EIE EFFECTS BY CHOICE OF OBSERVATION VOLUME [J].
GALLEY, PJ ;
HIEFTJE, GM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1994, 49 (07) :703-724