Development of robust calibration models in near infra-red spectrometric applications

被引:140
作者
Swierenga, H
Wülfert, F
de Noord, OE
de Weijer, AP
Smilde, AK
Buydens, LMC
机构
[1] Catholic Univ Nijmegen, Fac Sci, Analyt Chem Lab, NL-6525 ED Nijmegen, Netherlands
[2] Univ Amsterdam, Dept Chem Engn Proc Anal & Chemometrics, NL-1018 WV Amsterdam, Netherlands
[3] Akzo Nobel Cent Res, NL-6800 SB Arnhem, Netherlands
[4] Shell Int Chem BV, Shell Res & Technol Ctr, NL-1030 BN Amsterdam, Netherlands
关键词
robust calibration; near infra-red spectrometry;
D O I
10.1016/S0003-2670(00)00718-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
When spectral variation caused by factors different from the parameter to be predicted (e.g. external variations in temperature) is present in calibration data, a common approach is to include this variation in the calibration model. For this purpose, the calibration sample spectra measured under standard conditions and the spectra of a smaller set measured under changed conditions are combined into one dataset and a global calibration model is calculated. However, if highly non-linear effects are present in the data, it may be impossible to capture this external variation in the model. Recently, a new technique, which is based on selection of robust variables, was proposed for constructing robust calibration models. In this technique, a calibration model is developed which uses a subset of spectral values that are insensitive to external variations. This new technique is compared with global calibration models for constructing robust models in spectrometric applications. Both techniques are applied to two different near infra-red (NIR) spectroscopic applications. The first is the determination of the ethanol, water, and iso-propanol concentrations in a ternary mixture of these components; the second is the determination of the density of heavy oil products. In both applications, the calibration set spectra have been measured at a standard sample temperature and a subset has been measured at sample temperatures deviating from the standard temperature. It has been found that models based on robust variable selection are similar or sometimes better than global calibration models with respect to their predictive ability at different sample temperatures. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:121 / 135
页数:15
相关论文
共 19 条
[1]  
AARTS E, 1989, SIMULATED ANNEALING, P13
[2]   Standardization of near-infrared spectrometric instruments [J].
Bouveresse, E ;
Hartmann, C ;
Massart, DL ;
Last, IR ;
Prebble, KA .
ANALYTICAL CHEMISTRY, 1996, 68 (06) :982-990
[3]   Elimination of uninformative variables for multivariate calibration [J].
Centner, V ;
Massart, DL ;
deNoord, OE ;
deJong, S ;
Vandeginste, BM ;
Sterna, C .
ANALYTICAL CHEMISTRY, 1996, 68 (21) :3851-3858
[4]   THE INFLUENCE OF DATA PREPROCESSING ON THE ROBUSTNESS AND PARSIMONY OF MULTIVARIATE CALIBRATION MODELS [J].
DENOORD, OE .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1994, 23 (01) :65-70
[5]   MULTIVARIATE CALIBRATION STANDARDIZATION [J].
DENOORD, OE .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1994, 25 (02) :85-97
[6]  
*EIG TECHN, PLS TOOLB US MATL VE
[7]   Random correlation in variable selection for multivariate calibration with a genetic algorithm [J].
JouanRimbaud, D ;
Massart, DL ;
deNoord, OE .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1996, 35 (02) :213-220
[8]   COMPUTER AIDED DESIGN OF EXPERIMENTS [J].
KENNARD, RW ;
STONE, LA .
TECHNOMETRICS, 1969, 11 (01) :137-&
[9]   Genetic algorithms applied to feature selection in PLS regression: how and when to use them [J].
Leardi, R ;
Gonzalez, AL .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1998, 41 (02) :195-207
[10]   INTERACTIVE VARIABLE SELECTION (IVS) FOR PLS .1. THEORY AND ALGORITHMS [J].
LINDGREN, F ;
GELADI, P ;
RANNAR, S ;
WOLD, S .