A comparison of low-dose inhaled budesonide plus theophylline and high-dose inhaled budesonide for moderate asthma

被引:246
作者
Evans, DJ
Taylor, DA
Zetterstrom, O
Chung, F
OConnor, BJ
Barnes, PJ
机构
[1] UNIV LONDON IMPERIAL COLL SCI TECHNOL & MED, NATL HEART & LUNG INST, DEPT THORAC MED, LONDON SW3 6LY, ENGLAND
[2] KAROLINSKA INST, THORAC CLIN, DIV RESP MED, STOCKHOLM, SWEDEN
关键词
D O I
10.1056/NEJM199711133372002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Inhaled glucocorticoids and oral theophylline are widely used to treat asthma. We compared the benefits of adding theophylline to inhaled glucocorticoid with those of doubling the dose of inhaled glucocorticoid in patients with persistent symptoms despite the use of inhaled glucocorticoid. Methods In a double-blind, placebo-controlled trial, we randomly assigned 62 patients to receive either 400 mu g of inhaled budesonide (low-dose budesonide) with 250 or 375 mg of theophylline (depending on body weight) or 800 mu g of inhaled budesonide (high-dose budesonide). All doses were given twice daily for three months. Lung function was measured serially, and patients kept records of peak expiratory flow, symptoms, and albuterol use. The effects of treatment on endogenous cortisol levels were also assessed. Results Both treatments resulted in improvements in lung function that were sustained throughout the study. As compared with treatment with high-dose budesonide, treatment with low-dose budesonide plus theophylline resulted in greater improvements in forced vital capacity (P = 0.03) and forced expiratory volume in one second (P = 0.03). There were significant and similar reductions in beta(2)-agonist use and the variability of peak expiratory flow, a correlate of bronchial hyperresponsiveness and the severity of asthma. Serum cortisol concentrations were significantly reduced in the group given high-dose budesonide (from a mean [+/-SE] of 18.4 +/- 2.4 mu g per deciliter to 15.9 +/- 2.1 mu g per deciliter, P = 0.02) but were unchanged in the other group. The median serum theophylline concentration was 8.7 mu g per milliliter (therapeutic range, 10 to 20) among those who received theophylline. Both treatments were well tolerated. Conclusions For patients with moderate asthma and persistent symptoms, low-dose inhaled budesonide with theophylline and high-dose inhaled budesonide produced similar benefits. Effects were achieved at theophylline concentrations below the recommended therapeutic range. The addition of low-dose theophylline to inhaled glucocorticoid may be preferable to and cheaper than increasing the dose of inhaled glucocorticoid. (C) 1997, Massachusetts Medical Society.
引用
收藏
页码:1412 / 1418
页数:7
相关论文
共 27 条
[1]  
[Anonymous], 1987, AM REV RESPIR DIS, V136, P225
[2]   DRUG-THERAPY - INHALED GLUCOCORTICOIDS FOR ASTHMA [J].
BARNES, PJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 332 (13) :868-875
[3]   THEOPHYLLINE IN THE MANAGEMENT OF ASTHMA - TIME FOR REAPPRAISAL [J].
BARNES, PJ ;
PAUWELS, RA .
EUROPEAN RESPIRATORY JOURNAL, 1994, 7 (03) :579-591
[4]   The costs of asthma [J].
Barnes, PJ ;
Jonsson, B ;
Klim, JB .
EUROPEAN RESPIRATORY JOURNAL, 1996, 9 (04) :636-642
[5]  
[British Thoracic Society Brit. Paediatric Association Research Unit of the Royal College of Physicians of London King's Fund Centre National Asthma Campaign Royal College of General Practitioners General Practitioners in Asthma Group British Association of Accident and Emergency Medicine British Paediatric Respiratory Group], 1993, THORAX, V48, pS1
[6]  
Crowder MJ, 1990, ANAL REPEATED MEASUR
[7]   A DOSE-RANGING STUDY OF FLUTICASONE PROPIONATE IN ADULT PATIENTS WITH MODERATE ASTHMA [J].
DAHL, R ;
LUNDBACK, B ;
MALO, JL ;
MAZZA, JA ;
NIEMINEN, MM ;
SAARELAINEN, P ;
BARNACLE, H .
CHEST, 1993, 104 (05) :1352-1358
[8]   THEOPHYLLINE SUPPRESSES HUMAN ALVEOLAR MACROPHAGE RESPIRATORY BURST THROUGH PHOSPHODIESTERASE INHIBITION [J].
DENT, G ;
GIEMBYCZ, MA ;
RABE, KF ;
WOLF, B ;
BARNES, PJ ;
MAGNUSSEN, H .
AMERICAN JOURNAL OF RESPIRATORY CELL AND MOLECULAR BIOLOGY, 1994, 10 (05) :565-572
[9]   ADDED SALMETEROL VERSUS HIGHER-DOSE CORTICOSTEROID IN ASTHMA PATIENTS WITH SYMPTOMS ON EXISTING INHALED CORTICOSTEROID [J].
GREENING, AP ;
IND, PW ;
NORTHFIELD, M ;
SHAW, G .
LANCET, 1994, 344 (8917) :219-224
[10]   DIFFERENTIAL-EFFECTS OF NONSELECTIVE AND SELECTIVE PHOSPHODIESTERASE INHIBITORS ON HUMAN EOSINOPHIL FUNCTIONS [J].
HATZELMANN, A ;
TENOR, H ;
SCHUDT, C .
BRITISH JOURNAL OF PHARMACOLOGY, 1995, 114 (04) :821-831