RIVCAM: a simple video-based kinematic analysis for clinical disorders of gait

被引:27
作者
Churchill, AJG [1 ]
Halligan, PW
Wade, DT
机构
[1] Univ Cent Lancashire, Dept Psychol, Preston PR1 2HE, Lancs, England
[2] Univ Wales Coll Cardiff, Sch Psychol, Cardiff CF1 3YG, S Glam, Wales
[3] Rivermead Rehabil Ctr, Oxford OX1 4XD, England
关键词
gait; image analysis; kinematics; movement recording; video recording;
D O I
10.1016/S0169-2607(01)00191-2
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper describes the development of and reports on the accuracy of the Rivermead video-based clinical gait analysis method (RIVCAM), a simple and comparatively inexpensive movement recording system, which operates at 50 Hz. The system comprises five basic steps; firstly subjects are recorded using a PAL video camera with white markers affixed to the leg. Second, the video footage is digitised onto a computer. Thirdly, a program analyses each frame of footage to locate the position of white markers located on the subject's leg. Fourth, the data are calibrated (turned into real world co-ordinates) and the markers on the legs are identified (such as, heel, toe, etc.). Finally, a kinematic analysis is performed on the data, which not only produces a range of relevant spatio-temporal parameters (such as gait velocity, cadence and stride length), but also determines the joint angles at the hip, knee and ankle during the gait cycle. Overall the system has a reasonable constant and variable error; in a recorded scene measuring 2.6 x 1.6 m and divided into a 3 x 3 grid, a 400 mm bar was recorded, on average, as being 401.1 mm with a standard deviation (S.D.) of 2.97 mm. Although not without shortcomings when compared with more expensive and complicated systems, the RIVCAM system represents a valid, reliable and affordable way of collecting objective measures of gait in a busy therapy setting. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:197 / 209
页数:13
相关论文
共 23 条
[1]   Comfortable and maximum walking speed of adults aged 20-79 years: Reference values and determinants [J].
Bohannon, RW .
AGE AND AGEING, 1997, 26 (01) :15-19
[2]  
BRANDSTATER ME, 1983, ARCH PHYS MED REHAB, V64, P583
[3]   Gait analysis in the therapeutic environment [J].
Coutts, F .
MANUAL THERAPY, 1999, 4 (01) :2-10
[4]   INTERRATER RELIABILITY OF VIDEOTAPED OBSERVATIONAL GAIT-ANALYSIS ASSESSMENTS [J].
EASTLACK, ME ;
ARVIDSON, J ;
SNYDERMACKLER, L ;
DANOFF, JV ;
MCGARVEY, CL .
PHYSICAL THERAPY, 1991, 71 (06) :465-472
[5]  
HAGGARD P, 1990, J MOTOR BEHAV, V22, P315
[6]   An assessment of gait analysis in the rehabilitation of children with walking difficulties [J].
Hailey, D ;
Tomie, JA .
DISABILITY AND REHABILITATION, 2000, 22 (06) :275-280
[7]   AGE-RELATED-CHANGES IN SPEED OF WALKING [J].
HIMANN, JE ;
CUNNINGHAM, DA ;
RECHNITZER, PA ;
PATERSON, DH .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1988, 20 (02) :161-166
[8]   VISUAL ASSESSMENT OF HEMIPLEGIC GAIT FOLLOWING STROKE - PILOT-STUDY [J].
HUGHES, KA ;
BELL, F .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1994, 75 (10) :1100-1107
[9]   Visual gait analysis: the development of a clinical assessment and scale [J].
Lord, SE ;
Halligan, PW ;
Wade, DT .
CLINICAL REHABILITATION, 1998, 12 (02) :107-119
[10]   Validity and reliability of a kinematic protocol for determining foot contact events [J].
Mickelborough, J ;
van der Linden, ML ;
Richards, J ;
Ennos, AR .
GAIT & POSTURE, 2000, 11 (01) :32-37