Femoral anatomy, computed tomography and computer-aided design of prosthetic implants

被引:36
作者
Adam, F [1 ]
Hammer, DS
Pape, D
Kohn, D
机构
[1] Univ Saarland, Dept Orthopaed Surg, D-66424 Homburg, Saar, Germany
[2] Univ Saarlandes Kliniken, Orthopad Klin & Poliklin, D-66421 Homburg, Saar, Germany
关键词
femur; anatomy; computed tomography; computer-aided-design; prosthetic implants;
D O I
10.1007/s00402-001-0361-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Precise digital data of the internal femoral anatomy are necessary to develop new prosthetic implants with computer-aided design (CAD) techniques. Thirty human cadaveric femurs of central European origin were analysed by high precision computed tomography (CT) using thin slice and high resolution imaging. The CT data were image processed with thresholding to obtain a reconstruction of the cortical bone geometry. The CT threshold for cortical bone was optimized by comparison with saw cuts of macerated femurs. For each specimen a three-dimensional (3D) model of the cortical femur was calculated by the CAD system based on the processed CT data. Virtual 3D models of the 30 femurs were used to adjust a hypothetical stem to the proximal femur anatomy by repeated virtual implantations. The CAD system allowed for evaluation of anatomical parameters after hip reconstruction, amount of bone removal, and cortical bone contact. The fit and fill of the stem could be tested before clinical application and implant-related problems could be corrected.
引用
收藏
页码:262 / 268
页数:7
相关论文
共 28 条
[1]
Determination of the Hounsfield value for CT-based design of custom femoral stems [J].
Aamodt, A ;
Kvistad, KA ;
Andersen, E ;
Lund-Larsen, J ;
Eine, J ;
Benum, P ;
Husby, OS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (01) :143-147
[2]
The internal calcar septum (femoral thigh spur) in computed tomography and conventional radiography [J].
Adam, F ;
Hammer, DS ;
Pape, D ;
Kohn, D .
SKELETAL RADIOLOGY, 2001, 30 (02) :77-83
[3]
BARGAR WL, 1989, CLIN ORTHOP RELAT R, V249, P73
[4]
MECHANICAL PROPERTY DISTRIBUTIONS IN THE CANCELLOUS BONE OF THE HUMAN PROXIMAL FEMUR [J].
BROWN, TD ;
FERGUSON, AB .
ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (03) :429-437
[5]
CAPELLO WN, 1989, CLIN ORTHOP RELAT R, V249, P56
[6]
Clarke H J, 1992, J Arthroplasty, V7, P235, DOI 10.1016/0883-5403(92)90042-O
[7]
DAI KR, 1985, ORTHOP T, V10, P256
[8]
Measurement of thickness and density of thin structures by computed tomography: A simulation study [J].
Dougherty, G ;
Newman, D .
MEDICAL PHYSICS, 1999, 26 (07) :1341-1348
[9]
3-DIMENSIONAL ANATOMY OF THE CANCELLOUS STRUCTURES WITHIN THE PROXIMAL FEMUR FROM COMPUTED-TOMOGRAPHY DATA [J].
ELKE, RPE ;
CHEAL, EJ ;
SIMMONS, C ;
POSS, R .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (04) :513-523
[10]
FIT AND FILL - FASHIONABLE FACT OR FANTASY [J].
HORNE, G .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (01) :4-5