Experimental study on the double-evaporator thermosiphon for cooling HTS (high temperature superconductor) system

被引:14
作者
Lee, Junghyun [1 ]
Ko, Junseok [1 ]
Kim, Youngkwon [1 ]
Jeong, Sangkwon [1 ]
Sung, Taehyun [2 ]
Han, Younghee [2 ]
Lee, Jeong-Phil [2 ]
Jung, Seyong [2 ]
机构
[1] Korea Adv Inst Sci & Technol, Cryogen Engn Lab, Dept Mech Engn, Taejon 305701, South Korea
[2] Korea Elect Power Res Inst, Superconduct & Applicat Grp, Taejon 305380, South Korea
关键词
Double-evaporator thermosiphon; HTS system; Sub-atmospheric pressure; Thermal resistance model;
D O I
10.1016/j.cryogenics.2009.04.004
中图分类号
O414.1 [热力学];
学科分类号
摘要
A cryogenic thermosiphons is an efficient heat transfer device between a cryocooler and a thermal load that is to be cooled. This paper presents an idea of thermosiphon which contains two vertically-separated evaporators. This unique configuration of the thermosiphon is suitable for the purpose of cooling simultaneously two superconducting bearings of the HTS (high temperature superconducting) flywheel system at the same temperature. A so-called double-evaporator thermosiphon was designed, fabricated and tested using nitrogen as the working fluid under sub-atmospheric pressure condition. The interior thermal condition of the double-evaporator thermosiphon was examined in detail during its cool-down process according to the internal thermal states. The double-evaporator thermosiphon has operated successfully at steady-state operation under sub-atmospheric pressure. At the heat flow of 10.6 W, the total temperature difference of the thermosiphon was only 1.59 K and the temperature difference between the evaporators was 0.64 K. The temperature difference of two evaporators is attributed to the conductive thermal resistance of the adiabatic section between the evaporators. The method to reduce this temperature difference has been investigated and presented in this paper. The proper area selection of condenser, evaporator 1, and evaporator 2 was studied by using thermal resistance model to optimize the performance of a thermosiphon. The superior heat transfer characteristic of the double-evaporator thermosiphon without involving any cryogenic pump can be a great potential advantage for cooling HTS bulk modules that are separated vertically. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:390 / 397
页数:8
相关论文
共 13 条
[1]  
Beduz C., 1988, Advances in Cryogenic Engineering, V33, P363
[2]  
CHRISTIE R, 2004, ADV CRYOGENIC ENG B, V49, P1079, DOI DOI 10.1063/1.1774792
[3]  
DUNN PD, 1977, HEAT PIPES
[4]  
Faghri Amir., 1995, HEAT PIPE SCI TECHNO
[5]  
ICHIKAWA N, 1990, ADV CRYO ENG, V35
[6]  
IMURA H, 1979, JPN RES, V2, P41
[7]   Experimental investigation on the detachable thermosiphon for conduction-cooled superconducting magnets [J].
Jeong, Sangkwon ;
Kim, Youngkwon ;
Noh, Changhyun ;
Kim, Seokho ;
Jin, Hongbeom .
CRYOGENICS, 2006, 46 (10) :705-710
[8]  
KRABBES G., 2006, High Temperature Superconductor Bulk Materials
[9]   An experimental study of heat transfer characteristics of a two-phase nitrogen thermosyphon over a large dynamic range operation [J].
Nakano, A ;
Shiraishi, M ;
Nishio, M ;
Murakami, M .
CRYOGENICS, 1998, 38 (12) :1259-1266
[10]   BOILING REGIMES IN A CLOSED 2-PHASE THERMOSIPHON [J].
NIRO, A ;
BERETTA, GP .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1990, 33 (10) :2099-2110