Comparison of hydroxyapatite and hydroxyapatite tricalcium-phosphate coatings

被引:34
作者
Jinno, T
Davy, DT
Goldberg, VM
机构
[1] Case Western Reserve Univ, Dept Mech & Aerosp Engn, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Orthopaed, Sch Med, Cleveland, OH 44106 USA
关键词
hydroxyapatite (HA) coating; hydroxyapatite/tricalcium-phosphate (HA/TCP); implant fixation; osseointegration; bone ongrowth;
D O I
10.1054/arth.2002.34821
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study compared the effects of hydroxyapatite (HA) coating and biphasic HA/tricalcium-phosphate (HA/TCP) coating on the osseointegration of grit-blasted titanium-alloy implants. Each coated implant was compared with uncoated grit-blasted implants as well. The implants were press-fit into the medullary canal of rabbit femora, and their osseointegration was evaluated 3 to 24 weeks after surgery. The coated implants had significantly (P<.05) greater new bone ongrowth than the uncoated implants (HA, 56.1 +/- 3.1%; HA/TCP, 53.8 +/- 2.6%; uncoated, 32.2 +/- 1.4% of the implant perimeter, 12 weeks). Unmineralized tissue (cartilage and osteoid) was seen on the uncoated implants but never on the coated implants. The coated implants had significantly (P<.05) greater interfacial shear strength than the uncoated implants (HA, 4.1 +/- 0.4 MPa; HA/TCP, 4.8 +/- 0.5 MPa; uncoated, 2.6 +/- 0.2 MPa, 12 weeks). There was no difference between HA and HA/TCP coating in regard to new bone growth or interfacial shear strength. These data show a comparable enhancement effect of HA and HA/TCP coatings on the osseointegration of titanium-alloy implants.
引用
收藏
页码:902 / 909
页数:8
相关论文
共 20 条
[1]   HYDROXYAPATITE-COATED FEMORAL STEMS - HISTOLOGICAL ANALYSIS OF COMPONENTS RETRIEVED AT AUTOPSY [J].
BAUER, TW ;
GEESINK, RCT ;
ZIMMERMAN, R ;
MCMAHON, JT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (10) :1439-1452
[2]  
BLOEBAUM RD, 1994, CLIN ORTHOP RELAT R, P19
[3]   THE INFLUENCE OF SURFACE-BLASTING ON THE INCORPORATION OF TITANIUM-ALLOY IMPLANTS IN A RABBIT INTRAMEDULLARY MODEL [J].
FEIGHAN, JE ;
GOLDBERG, VM ;
DAVY, D ;
PARR, JA ;
STEVENSON, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77 (09) :1380-1395
[4]   OSSEOINTEGRATION OF MACROPOROUS CALCIUM-PHOSPHATE CERAMICS HAVING A DIFFERENT CHEMICAL-COMPOSITION [J].
FRAYSSINET, P ;
TROUILLET, JL ;
ROUQUET, N ;
AZIMUS, E ;
AUTEFAGE, A .
BIOMATERIALS, 1993, 14 (06) :423-429
[5]  
GEESINK RGT, 1987, CLIN ORTHOP RELAT R, P147
[6]   EFFECT OF SURFACE-ROUGHNESS OF HYDROXYAPATITE-COATED TITANIUM ON THE BONE-IMPLANT INTERFACE SHEAR-STRENGTH [J].
HAYASHI, K ;
INADOME, T ;
TSUMURA, H ;
NAKASHIMA, Y ;
SUGIOKA, Y .
BIOMATERIALS, 1994, 15 (14) :1187-1191
[7]   COMPARISON OF BONE-IMPLANT INTERFACE SHEAR-STRENGTH OF HYDROXYAPATITE-COATED AND ALUMINA-COATED METAL IMPLANTS [J].
INADOME, T ;
HAYASHI, K ;
NAKASHIMA, Y ;
TSUMURA, H ;
SUGIOKA, Y .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (01) :19-24
[8]   Total hip arthroplasty with hydroxyapatite-coated prostheses [J].
Jaffe, WL ;
Scott, DF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (12) :1918-1934
[9]  
Jinno T, 1998, J BIOMED MATER RES, V42, P20, DOI 10.1002/(SICI)1097-4636(199810)42:1<20::AID-JBM4>3.0.CO
[10]  
2-Q