Steady state and transient QCM solutions at the metal | solution interface

被引:17
作者
Kanazawa, KK [1 ]
机构
[1] Stanford Univ, Dept Chem Engn, Stanford, CA 94305 USA
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 2002年 / 524卷
关键词
biosensors; electrochemical quartz crystal microbalance (EQCM); quartz microbalance simulation; transient methods; electrified interface;
D O I
10.1016/S0022-0728(02)00752-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The quartz crystal microbalance (QCM) is seeing a rapid increase in new applications and new instrumentation techniques. It is increasingly evident that this sensor provides not only mass data, but can provide information relative to the mechanical properties of deposited Films as well. Determining film properties from the measured electrical properties of the QCM resonator requires a modeling of the effects of the film on the electrical behavior of the resonator. We show that the complete electro-mechanical model can provide descriptions of the effects of film properties on resonator behavior in a number of formats to include not only the standard steady-state behavior, but also the transient responses used in a recent new measurement technique. The use of a single model for all techniques will permit comparisons among the results. (0 2002 Published by Elsevier Science B.V.
引用
收藏
页码:103 / 109
页数:7
相关论文
共 19 条
[1]   Modeling the responses of thickness-shear mode resonators under various loading conditions [J].
Bandey, HL ;
Martin, SJ ;
Cernosek, RW ;
Hillman, AR .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :2205-2214
[2]   SOME NEW CONCEPTS ON FACTORS INFLUENCING THE OPERATIONAL FREQUENCY OF LIQUID-IMMERSED QUARTZ MICROBALANCES [J].
BARNES, C .
SENSORS AND ACTUATORS A-PHYSICAL, 1992, 30 (03) :197-202
[3]   IMPEDANCE ANALYSIS OF QUARTZ OSCILLATORS, CONTACTED ON ONE SIDE WITH A LIQUID [J].
BECK, R ;
PITTERMANN, U ;
WEIL, KG .
BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1988, 92 (11) :1363-1368
[4]   IMPROVED QUARTZ CRYSTAL MICROBALANCE TECHNIQUE [J].
BENES, E .
JOURNAL OF APPLIED PHYSICS, 1984, 56 (03) :608-626
[5]  
BROWN CE, 1998, M ABSTR 194 EL SOC, V2, P1
[6]   An electronic oscillator with automatic gain control: EQCM applications [J].
Chagnard, C ;
Gilbert, P ;
Watkins, AN ;
Beeler, T ;
Paul, DW .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 32 (02) :129-136
[7]   Electrochemical quartz crystal impedance study of redox hydrogel mediators for amperometric enzyme electrodes [J].
Etchenique, RA ;
Calvo, EJ .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4833-4841
[8]   VISCOELASTIC PROPERTIES OF THIN-FILMS PROBED WITH A QUARTZ-CRYSTAL RESONATOR [J].
JOHANNSMANN, D ;
MATHAUER, K ;
WEGNER, G ;
KNOLL, W .
PHYSICAL REVIEW B, 1992, 46 (12) :7808-7815
[9]  
Kanazawa KK, 1997, FARADAY DISCUSS, V107, P77
[10]   INVESTIGATION OF FILM-THICKNESS DETERMINATION BY OSCILLATING QUARTZ RESONATORS WITH LARGE MASS LOAD [J].
LU, CS ;
LEWIS, O .
JOURNAL OF APPLIED PHYSICS, 1972, 43 (11) :4385-&