Shaking table test of a 1:20 scale high-rise building with a transfer plate system

被引:72
作者
Li, C. S. [1 ]
Lam, S. S. E.
Zhang, M. Z.
Wong, Y. L.
机构
[1] Hong Kong Polytech Univ, Dept Civil & Struct Engn, Hong Kong, Hong Kong, Peoples R China
[2] China Seismol Bur, Inst Engn Mech, Harbin 150080, Peoples R China
来源
JOURNAL OF STRUCTURAL ENGINEERING-ASCE | 2006年 / 132卷 / 11期
关键词
buildings; high-rise; seismic effects; plates; concrete; reinforced; earthquakes; shake table tests;
D O I
10.1061/(ASCE)0733-9445(2006)132:11(1732)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The reinforced concrete building considered in this study has 34 typical floors above a 2.7 m thick transfer plate and a three-level podium. The transfer plate is a reinforced concrete thick plate that transfers the loads from the walls at the typical floors to widely spaced columns in the three-level podium. A microconcrete model representing the high-rise building was constructed in 1:20 scale. Shaking table tests were conducted and the model was subjected to earthquake actions representing minor, moderate, major, and supermajor earthquakes for a region of moderate seismicity, with basic seismic intensity at the VIIth degree pursuant to GB50011-2001. Seismic performance was qualitatively assessed, and it is predicted that the prototype building will not collapse when subjected to major earthquakes. The majority of the damage and failure occurred at the story above the transfer plate. To minimize the damage, it is desirable to strengthen the walls between the 4th and 15th floors as well as reducing any change in stiffness within the transfer plate zone. Data obtained from the shaking table tests were analyzed. Spectral frequencies of the acceleration spectra estimated by the fast Fourier transform method and deformation measurements are good indicators on structural damage. Plots of acceleration against displacement would be useful in assessing the locations of structural damage. The use of the ratio of lateral stiffness to check the existence of a soft story may not be appropriate for high-rise buildings. However, story drift relates well with the degree of structural damage.
引用
收藏
页码:1732 / 1744
页数:13
相关论文
共 18 条
  • [1] Aoyama H., 2001, DESIGN MODERN HIGH R
  • [2] BLONDET JM, 1980, UCBEERC8042
  • [3] *BSI, 1985, BS81101985 BSI
  • [4] Elwood KJ, 2003, PEER Report No 2003/01
  • [5] He L., 1992, SEISMIC BEHAV FLANGE
  • [6] HUANG X, 2002, P INT C ADV NEW CHAL
  • [7] KRAWINKLER H, 1982, DYNAMIC MODELING CON, P1
  • [8] LAM SSE, 2002, SHAKING TABLE TESTS
  • [9] Dependent lung opacity at thin-section CT: Evaluation by spirometrically-gated CT of the influence of lung volume
    Lee, KN
    Yoon, SK
    Sohn, CH
    Choi, PJ
    Webb, WR
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2002, 3 (01) : 24 - 29
  • [10] LI CS, 2003, P 3 INT C STRUCT ENG, P339