Standardized abnormal interpretation and cancer detection ratios to assess reading volume and reader performance in a breast screening program

被引:95
作者
Kan, L
Olivotto, IA
Burhenne, LJW
Sickles, EA
Coldman, AJ
机构
[1] Screening Mammog Program British Columbia, Vancouver, BC V5Z 1G1, Canada
[2] British Columbia Canc Agcy, Vancouver, BC V5Z 4E6, Canada
[3] Univ Calif San Francisco, Med Ctr, Dept Radiol, San Francisco, CA 94143 USA
[4] Univ British Columbia, Fac Med, Dept Radiol, Vancouver, BC, Canada
[5] Univ British Columbia, Fac Med, Dept Surg, Vancouver, BC, Canada
[6] Univ British Columbia, Fac Sci, Dept Stat, Vancouver, BC, Canada
关键词
breast neoplasms; diagnosis; radiography; breast radiography; quality assurance; cancer screening;
D O I
10.1148/radiology.215.2.r00ma42563
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the relationship between annual screening volume and radiologist performance in the Screening Mammography Program of British Columbia, Canada. MATERIALS AND METHODS: Standardized abnormal interpretation ratios and standardized cancer detection ratios were constructed for 35 readers with at least 3 years of experience with the Screening Mammography Program of British Columbia. The ratios were used to compare individual reader performance with the mean program performance after adjustment for the age and screening history (first versus subsequent screening examinations) of the women who underwent screening. RESULTS: The mean standardized abnormal interpretation ratio was better for readers of 2,000-2,999 (n = 8) and 3,000-3,999 (n = 9) screening mammograms per year than for those of less than 2,000 (n = 9) and 4,000-5,199 (n = 9) screening mammograms per year. Differences in the mean standardized abnormal interpretation ratios were significant (P < .05) between the readers of less than 2,000 and of 2,000-2,999 screening mammograms per year, between readers of less than 2,000 and of 3,000-3,999 screening mammograms per year and between readers of 3,000-3,999 and of 4,000-5,199 screening mammograms per year. The mean standardized cancer detection ratio improved gradually with increasing annual volume, but the differences between groups were not statistically significant. Five of the eight readers of 2,000-2,999 mammograms were reading 2,475 or more screening mammograms per year. CONCLUSION: Standardized abnormal interpretation ratios and standardized cancer detection ratios provide a method of comparing two important performance measures in a screening program. A minimum of 2,500 interpretations per year is associated with lower abnormal interpretation rates and average or better cancer detection rates.
引用
收藏
页码:563 / 567
页数:5
相关论文
共 18 条
[1]  
Blanks R G, 1996, J Med Screen, V3, P79
[2]   QUALITY ASSURANCE AND CANCER-DETECTION RATES IN A PROVINCIAL SCREENING MAMMOGRAPHY PROGRAM - WORK-IN-PROGRESS [J].
BRYANT, HE ;
DESAUTELS, JEL ;
CASTOR, WR ;
HORECZKO, N ;
JACKSON, F ;
MAH, Z .
RADIOLOGY, 1993, 188 (03) :811-816
[3]   THE BRITISH-COLUMBIA MAMMOGRAPHY SCREENING-PROGRAM - EVALUATION OF THE 1ST 15 MONTHS [J].
BURHENNE, LJW ;
HISLOP, TG ;
BURHENNE, HJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (01) :45-49
[4]  
Ciatto S, 1994, J Med Screen, V1, P188
[5]   SCREENING MAMMOGRAPHY IN BRITISH-COLUMBIA - 1988-1993 [J].
CLAY, MG ;
HISLOP, TG ;
KAN, L ;
OLIVOTTO, IA ;
BURHENNE, LJW .
AMERICAN JOURNAL OF SURGERY, 1994, 167 (05) :490-492
[6]  
Fracheboud J, 1998, INT J CANCER, V75, P694, DOI 10.1002/(SICI)1097-0215(19980302)75:5<694::AID-IJC6>3.0.CO
[7]  
2-U
[8]   Results from the Ontario breast screening program, 1990-1995 [J].
Libstug, AR ;
Moravan, V ;
Aitken, SE .
JOURNAL OF MEDICAL SCREENING, 1998, 5 (02) :73-80
[9]  
*NAT HLTH SERV BRE, 1990, QUAL ASS GUID RAD
[10]  