Intraoperative 3D Imaging in Calcaneal Fracture Care-Clinical Implications and Decision Making

被引:71
作者
Geerling, Jens [1 ]
Kendoff, Daniel [1 ]
Citak, Musa [1 ]
Zech, Stefan [3 ]
Gardner, Michael J. [2 ]
Huefner, Tobias [1 ]
Krettek, Christian [1 ]
Richter, Martinus [3 ]
机构
[1] Hannover Med Sch, Trauma Dept, D-3000 Hannover, Germany
[2] Hosp Special Surg, Dept Orthoped Surg, New York, NY 10021 USA
[3] Coburg Clin Ctr, Dept Trauma Orthopaed & Foot Surg, Coburg, Germany
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2009年 / 66卷 / 03期
关键词
MOBILE C-ARM; DISPLACED INTRAARTICULAR FRACTURES; INTERNAL-FIXATION; OPERATIVE TREATMENT; CONTACT CHARACTERISTICS; NONOPERATIVE TREATMENT; SUBTALAR JOINT; OPEN REDUCTION; MANAGEMENT; ISO-C-3D;
D O I
10.1097/TA.0b013e31816275c7
中图分类号
R4 [临床医学];
学科分类号
100218 [急诊医学];
摘要
Background: In operative calcaneal fracture care malposition of screws and joint line incongruity frequently remain unrecognized using fluoroscopy intraoperatively, and are frequently only recognized on postoperative computed tomography scans. The purpose of this study was to analyze the feasibility and utility of a new C-arm-based three-dimensional imaging technology for calcaneal trauma care. Methods: The C-arm-based three-dimensional imaging device (ISO-C-3D) was used in 32 patients during a 2-year period. Patients were indicated for open reduction and internal fixation using standard techniques and fluoroscopy. After reduction and implant placement was determined to be correct, the ISO-C-3D procedure was performed. The time for setup and use, and the consequences were recorded. An assessment was obtained from the surgeon regarding the feasibility and the adequacy and quality of the data provided, using a Visual Analog Scale. Results: The average total time required for ISO-C-3D use was 610 seconds. The information obtained from the scan led the surgeon to alter the reduction or screw placement during the procedure in 41% of the patients. Surgeons rating according to a Visual Analog Scale: feasibility 9.5, accuracy and quality 9.2, clinical benefit 8.2. Conclusion: Intraoperative three-dimensional visualization with the ISOC-3D provides important information in the operative treatment of calcaneal fractures which cannot always be obtained from plain films or standard fluoroscopy alone. The use of the device adds minimal time to the overall procedure, and was found to be extremely useful in evaluating reduction and implant position intraoperatively in calcaneal fractures.
引用
收藏
页码:768 / 773
页数:6
相关论文
共 35 条
[1]
INTERNAL-FIXATION OF CALCANEUS FRACTURES - AN ANATOMICAL STUDY OF STRUCTURES AT RISK [J].
ALBERT, MJ ;
WAGGONER, SM ;
SMITH, JW .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1995, 9 (02) :107-112
[2]
BENIRSCHKE SK, 1993, CLIN ORTHOP RELAT R, P128
[3]
BEZES H, 1993, CLIN ORTHOP RELAT R, P55
[4]
Bischoff M, 2004, UNFALLCHIRURG, V107, P712, DOI 10.1007/s00113-004-0811-1
[5]
An economic evaluation of operative compared with nonoperative management of displaced intra-articular calcaneal fractures [J].
Brauer, CA ;
Manns, BJ ;
Ko, M ;
Donaldson, C ;
Buckley, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (12) :2741-2749
[6]
Operative compared with nonoperative treatment of displacedintra-articular calcaneal fractures - A prospective, randomized, controlled multicenter trial [J].
Buckley, R ;
Tough, S ;
McCormack, R ;
Pate, G ;
Leighton, R ;
Petrie, D ;
Galpin, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (10) :1733-1744
[7]
CARR JB, 1994, ORTHOP CLIN N AM, V25, P665
[8]
COMPUTERIZED-TOMOGRAPHY SCANNING OF ACUTE INTRAARTICULAR FRACTURES OF THE CALCANEUS - A NEW CLASSIFICATION-SYSTEM [J].
CROSBY, LA ;
FITZGIBBONS, T .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (06) :852-859
[9]
Intra-articular fractures of the calcaneum: Why such controversy? [J].
Eastwood, DM ;
Phipp, L .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1997, 28 (04) :247-259
[10]
Euler E, 2001, UNFALLCHIRURG, V104, P839, DOI 10.1007/s001130170055