Asymmetry of the total body water prediction bias using the impedance index

被引:31
作者
Piccoli, A
Pillon, L
Favaro, E
机构
[1] Institute of Internal Medicine, Division of Nephrology, University of Padova, Padova
[2] Istituto di Medicina Interna, Cattedra di Nefrologia, I-35128 Padova, Via Giustiniani
关键词
total body water; bioelectrical impedance analysis; fluid balance; body cell mass; impedance index;
D O I
10.1016/S0899-9007(97)91282-X
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Our purpose was to prove on a geometric basis that the bias of total body water (TBW) prediction equations based on the impedance index is far greater in fluid overloading than in dehydration. We used formal evaluation of conventional bioimpedance regression equations in both normal and abnormal body fluid status. We plotted the hyperboloid function generated from a standard prediction equation for the TBW over the resistance-reactance (RXc) plane containing the bivariate tolerance intervals (ellipses) of the healthy population. The equation estimated 35 L TBW for the average man (both sexes) of 170 cm height. Leaving the center of the tolerance ellipses, over which the function was relatively flat, the predicted TBW rapidly increased to absurd values for the shorter vectors, indicating fluid overloading (e.g., > 100 L for R < 170 ohm). Migration of the longer impedance vectors beyond the upper pole of 95% tolerance ellipse, which is in the dehydration region, produced less biased estimates of TBW (e.g., < 22 L for the extreme R values > 850 ohm). Different formulas produced TBW prediction bias of the same order. Due to the hyperbolic shape, functions of the impedance index are critically dependent on the region of the RXc plane where they are calculated and they produce misleading results in patients with fluid overload. (C) Elsevier Science Inc. 1997.
引用
收藏
页码:438 / 441
页数:4
相关论文
共 13 条
[1]  
FULCO CS, 1992, J APPL PHYSIOL, V76, P2181
[2]   COMPARISON OF ABILITIES OF VARIOUS INTERPRETATIONS OF BIOELECTRICAL-IMPEDANCE TO PREDICT REFERENCE METHOD BODY-COMPOSITION ASSESSMENT [J].
FULLER, NJ .
CLINICAL NUTRITION, 1993, 12 (04) :236-242
[3]  
GUYTON AC, 1982, HUMAN PHYSL MECH DIS, P240
[4]   EVALUATION OF MULTIFREQUENCY BIOIMPEDANCE ANALYSIS FOR THE ASSESSMENT OF EXTRACELLULAR AND TOTAL-BODY WATER IN SURGICAL PATIENTS [J].
HANNAN, WJ ;
COWEN, SJ ;
FEARON, KCH ;
PLESTER, CE ;
FALCONER, JS ;
RICHARDSON, RA .
CLINICAL SCIENCE, 1994, 86 (04) :479-485
[5]  
KUSHNER RF, 1992, J AM COLL NUTR, V11, P199
[6]   IS THE IMPEDANCE INDEX (HT2/R) SIGNIFICANT IN PREDICTING TOTAL-BODY WATER [J].
KUSHNER, RF ;
SCHOELLER, DA ;
FJELD, CR ;
DANFORD, L .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1992, 56 (05) :835-839
[7]   VALIDATION OF TETRAPOLAR BIOELECTRICAL IMPEDANCE METHOD TO ASSESS HUMAN-BODY COMPOSITION [J].
LUKASKI, HC ;
BOLONCHUK, WW ;
HALL, CB ;
SIDERS, WA .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (04) :1327-1332
[8]  
PATEL R, 1995, CRIT CARE MED S, V23, pA27
[9]   BIVARIATE NORMAL VALUES OF THE BIOELECTRICAL-IMPEDANCE VECTOR IN ADULT AND ELDERLY POPULATIONS [J].
PICCOLI, A ;
NIGRELLI, S ;
CABERLOTTO, A ;
BOTTAZZO, S ;
ROSSI, B ;
PILLON, L ;
MAGGIORE, Q .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1995, 61 (02) :269-270
[10]   A NEW METHOD FOR MONITORING BODY-FLUID VARIATION BY BIOIMPEDANCE ANALYSIS - THE RXC GRAPH [J].
PICCOLI, A ;
ROSSI, B ;
PILLON, L ;
BUCCIANTE, G .
KIDNEY INTERNATIONAL, 1994, 46 (02) :534-539