Improving the thromboresistivity of chemical sensors via nitric oxide release: Fabrication and in vivo evaluation of NO-releasing oxygen-sensing catheters

被引:104
作者
Schoenfisch, MH
Mowery, KA
Rader, MV
Baliga, N
Wahr, JA
Meyerhoff, ME
机构
[1] Univ Michigan, Dept Anesthesiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
关键词
D O I
10.1021/ac991370c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development and in vivo analytical performance of a nitric oxide (NO)-releasing amperometric oxygen sensor with greatly enhanced thromboresistivity are reported. Gas permeable coatings formulated with cross-linked silicone rubber (SR) containing NO-generating compounds (diazeniumdiolates) are shown to release NO for extended periods of time (>20 h) while reducing platelet adhesion and activation. Oxygen-sensing catheters prepared by dip-coating the NO-releasing films over the outer SR tubes of the implantable devices display similar analytical response properties in vitro (sensitivity, selectivity, response times) when compared to analogous sensors prepared without the NO release coatings. Superior analytical accuracy (relative to blood PO2 values measured in vitro) and greatly reduced thrombus formation on the outer surface of the sensors are observed in vivo (in canine model) with the NO release PO2 sensors compared to control sensors (without NO release) implanted simultaneously within the same animals. Based on these preliminary studies, the use of NO release polymers to fabricate catheter-style chemical sensors may be a potential solution to lingering biocompatibility and concomitant performance problems encountered when attempting to employ such devices for continuous intravascular measurements of blood gases and electrolytes.
引用
收藏
页码:1119 / 1126
页数:8
相关论文
共 42 条
[1]  
ANNICH GM, IN PRESS CRIT CARE M
[2]   Hematological aspects of biocompatibility - Review article [J].
Banerjee, R ;
Nageswari, K ;
Puniyani, RR .
JOURNAL OF BIOMATERIALS APPLICATIONS, 1997, 12 (01) :57-76
[3]   HEMOCOMPATIBILITY OF INVASIVE SENSORS [J].
BENMAKROHA, Y ;
ZHANG, S ;
ROLFE, P .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1995, 33 (06) :811-821
[4]   CONTINUOUS POLAROGRAPHIC MONITORING OF INTRA-ARTERIAL OXYGEN IN THE PERIOPERATIVE PERIOD [J].
BRATANOW, N ;
POLK, K ;
BLAND, R ;
KRAM, HB ;
LEE, TS ;
SHOEMAKER, WC .
CRITICAL CARE MEDICINE, 1985, 13 (10) :859-860
[5]  
CLARK LC, 1956, T AM SOC ART INT ORG, V2, P41
[6]   CHEMICAL SENSORS FOR BEDSIDE MONITORING OF CRITICALLY ILL PATIENTS [J].
COLLISON, ME ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1990, 62 (07) :A425-&
[7]   POTENTIOMETRIC COMBINATION ION CARBON-DIOXIDE SENSORS FOR INVITRO AND INVIVO BLOOD MEASUREMENTS [J].
COLLISON, ME ;
AEBLI, GV ;
PETTY, J ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1989, 61 (21) :2365-2372
[8]  
EICHORN JH, 1989, BLOOD GAS PREANALYTI
[9]   Thromboresistant chemical sensors using combined nitric oxide release ion sensing polymeric films [J].
EspadasTorre, C ;
Oklejas, V ;
Mowery, K ;
Meyerhoff, ME .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (09) :2321-2322
[10]  
ESPADASTORRE C, 1994, INTERFACE, V4, P41