An Event-Triggered Approach for Load Frequency Control With Supplementary ADP

被引:179
作者
Dong, Lu [1 ,2 ,3 ]
Tang, Yufei [4 ]
He, Haibo [4 ]
Sun, Changyin [1 ,2 ]
机构
[1] Southeast Univ, Sch Automat, Nanjing 210096, Jiangsu, Peoples R China
[2] Southeast Univ, Key Lab Measurement & Control Complex Syst Engn, Minist Educ, Nanjing 210096, Jiangsu, Peoples R China
[3] Univ Rhode Isl, Kingston, RI 02881 USA
[4] Univ Rhode Isl, Dept Elect Comp & Biomed Engn, Kingston, RI 02881 USA
基金
美国国家科学基金会; 中国国家自然科学基金;
关键词
Load frequency control (LFC); event-triggered design; proportional-integral (PI) controller; adaptive dynamic programming (ADP); communication and computation cost; POWER-SYSTEM STABILITY; TIME-VARYING DELAYS; LINEAR-SYSTEMS; WIND FARM; NETWORKS;
D O I
10.1109/TPWRS.2016.2537984
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
080906 [电磁信息功能材料与结构]; 082806 [农业信息与电气工程];
摘要
The modern power system is evolving towards a new generation of smart grid, with significant benefits from the latest computer-based communication network technologies. Furthermore, as the incremental deployment of phase measurements units (PMUs) and the use of Smart Meters, there will be a substantial increase of the real-time system measurements. Under this trend, event-triggered control (ETC) will play an important role in reducing the communication and computation cost. In this paper, a novel ETC architecture design for load frequency control (LFC) with supplementary adaptive dynamic programming (ADP) is presented. The primary proportional-integral (PI) controller uses different proportional and integral thresholds for updating the actions, while the supplementary ADP controller is updated in an aperiodic manner. A strategy for the parameters calculation is introduced in a systematic way, and theoretical analysis of the ultimate boundedness for the closed-loop event-triggered system is also included. Simulation studies are carried out on one-area and three-area IEEE LFC benchmarks, and the results demonstrate the efficiency and effectiveness of the proposed design.
引用
收藏
页码:581 / 589
页数:9
相关论文
共 38 条
[1]
[Anonymous], 1999, P 14 WORLD C IFAC BE
[2]
Romero JA, 2012, IV INTERNATIONAL CONGRESS ON ULTRA MODERN TELECOMMUNICATIONS AND CONTROL SYSTEMS 2012 (ICUMT), P219, DOI 10.1109/ICUMT.2012.6459668
[3]
Bevrani H, 2009, POWER ELECTRON POWER, P1, DOI 10.1007/978-0-387-84878-5_1
[4]
Load frequency control in two area power systems using fuzzy logic controller [J].
Çam, E ;
Kocaarslan, I .
ENERGY CONVERSION AND MANAGEMENT, 2005, 46 (02) :233-243
[5]
Ganesh V., 2012, INT J ADV RES ELECT, V1, P262
[6]
Analysis of load frequency control performance assessment criteria [J].
Gross, G ;
Lee, JW .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2001, 16 (03) :520-525
[7]
Approximate dynamic programming based supplementary reactive power control for DFIG wind farm to enhance power system stability [J].
Guo, Wentao ;
Liu, Feng ;
Si, Jennie ;
He, Dawei ;
Harley, Ronald ;
Mei, Shengwei .
NEUROCOMPUTING, 2015, 170 :417-427
[8]
Analysis of event-driven controllers for linear systems [J].
Heemels, W. P. M. H. ;
Sandee, J. H. ;
Van den Bosch, P. P. J. .
INTERNATIONAL JOURNAL OF CONTROL, 2008, 81 (04) :571-590
[9]
Periodic Event-Triggered Control for Linear Systems [J].
Heemels, W. P. M. H. ;
Donkers, M. C. F. ;
Teel, Andrew R. .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2013, 58 (04) :847-861
[10]
Delay-Dependent Stability for Load Frequency Control With Constant and Time-Varying Delays [J].
Jiang, L. ;
Yao, W. ;
Wu, Q. H. ;
Wen, J. Y. ;
Cheng, S. J. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2012, 27 (02) :932-941