Sciatic nerve regeneration through venous or nervous grafts in the rat

被引:54
作者
FoidartDessalle, M
Dubuisson, A
Lejeune, A
Severyns, A
Manassis, Y
Delree, P
Crielaard, JM
Bassleer, R
Lejeune, G
机构
[1] CHU SART TILMAN, DEPT NEUROSURG, B-4000 LIEGE, BELGIUM
[2] CHU SART TILMAN, LAB ONCOL, B-4000 LIEGE, BELGIUM
[3] CHR CITADELLE, DEPT HAND SURG, LIEGE, BELGIUM
[4] UNIV LIEGE, INST SCHWANN, HISTOL LAB, B-4000 LIEGE, BELGIUM
关键词
D O I
10.1006/exnr.1997.6542
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This study analyses the interest of isologous venous grafts filled with saline or with Schwann cells versus nerve grafts as guides for regeneration of the sciatic nerve in 35 Wistar rats, Electrophysiological parameters (conduction velocities and distal latencies of motor responses) and the functional index of De Medinacelli were measured several times from 1 month to 1 year after surgery. An histological analysis was performed on 2 control rats and on 3 rats killed 6 or 12 months after surgery: the total number of fibers was counted on a montage photoprint of the whole nerve, and the diameters of axons and the thickness of the myelin sheath were measured on digitized images. With a portion of nerve as guide, the regeneration is faster than with a vein. However, regeneration after 6 months is at least as good with a venous graft filled with Schwann cells, as assessed by electrophysiological, functional, and histological analysis. The addition of Schwann cells in grafted veins allows the nerve to regenerate through longer gaps than previously described (25 vs 15 mm). In order to assess the quality of nerve regeneration, functional, electrophysiological, and histological analysis are complementary. (C) 1997 Academic Press.
引用
收藏
页码:236 / 246
页数:11
相关论文
共 61 条
  • [1] BASIC FIBROBLAST GROWTH-FACTOR RELEASED FROM SYNTHETIC GUIDANCE CHANNELS FACILITATES PERIPHERAL-NERVE REGENERATION ACROSS LONG NERVE GAPS
    AEBISCHER, P
    SALESSIOTIS, AN
    WINN, SR
    [J]. JOURNAL OF NEUROSCIENCE RESEARCH, 1989, 23 (03) : 282 - 289
  • [2] FUNCTIONAL-EVALUATION OF COMPLETE SCIATIC, PERONEAL, AND POSTERIOR TIBIAL NERVE LESIONS IN THE RAT
    BAIN, JR
    MACKINNON, SE
    HUNTER, DA
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1989, 83 (01) : 129 - 136
  • [3] BOLIN LM, 1995, J NEUROCHEM, V64, P850
  • [4] BORA FW, 1987, J HAND SURG-AM, V12A, P685
  • [5] INTEROBSERVER AND INTRAOBSERVER RELIABILITY OF WALKING-TRACK ANALYSIS USED TO ASSESS SCIATIC-NERVE FUNCTION IN RATS
    BROWN, CJ
    EVANS, PJ
    MACKINNON, SE
    BAIN, JR
    MAKINO, AP
    HUNTER, DA
    HARE, G
    [J]. MICROSURGERY, 1991, 12 (02) : 76 - 79
  • [6] SELF-EVALUATION OF WALKING-TRACK MEASUREMENT USING A SCIATIC FUNCTION INDEX
    BROWN, CJ
    MACKINNON, SE
    EVANS, PJ
    BAIN, JR
    MAKINO, AP
    HUNTER, DA
    HARE, GMT
    [J]. MICROSURGERY, 1989, 10 (03) : 226 - 235
  • [7] CHIU DT, 1982, SURGERY, V91, P666
  • [8] AN INVIVO MODEL TO QUANTIFY MOTOR AND SENSORY PERIPHERAL-NERVE REGENERATION USING BIORESORBABLE NERVE GUIDE TUBES
    DASILVA, CF
    MADISON, R
    DIKKES, P
    CHIU, TH
    SIDMAN, RL
    [J]. BRAIN RESEARCH, 1985, 342 (02) : 307 - 315
  • [9] DEMEDINACELI L, 1990, MICROSURG, V11, P191
  • [10] EVANS DHL, 1954, J ANAT, V88, P465